首页 | 本学科首页   官方微博 | 高级检索  
     

电厂凝汽器污垢自动清洗纽带的阻力特性研究
引用本文:卿德藩,周立,俞天兰,彭德其,俞秀民.电厂凝汽器污垢自动清洗纽带的阻力特性研究[J].电站系统工程,2001,17(5):277-279.
作者姓名:卿德藩  周立  俞天兰  彭德其  俞秀民
作者单位:株洲工学院
基金项目:湖南省教委2000年重点课题
摘    要:通过压力降试验,指出自转清洗纽带开孔对流体阻力的影响,并计算出阻力系数,提出在电厂凝汽器中自转清洗纽带开孔面积比率的建议。

关 键 词:自转清洗纽带  压降特性  发电厂
文章编号:1005-006X(2001)05-0277-03
修稿时间:2000年11月14

Investigation on Effects of Automatic Cleaning Twisted Stripe on Fluid Resistance in Fouling Condenser in Power Plant
QING De-fan,ZHOU Li,YU Tian-lan,et al..Investigation on Effects of Automatic Cleaning Twisted Stripe on Fluid Resistance in Fouling Condenser in Power Plant[J].Power System Engineering,2001,17(5):277-279.
Authors:QING De-fan  ZHOU Li  YU Tian-lan  
Abstract:Through pressure drop tests, the effects of automatic cleaning twisted stripe with hole on fluid resistance are pointed out. The resistance coefficients are calculated. The hole-area ratio of automatic cleaning twisted stripe in the condenser in power plant is proposed.
Keywords:automatic cleaning twisted stripe  pressure drop characteristics  power plant  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏