首页 | 本学科首页   官方微博 | 高级检索  
     


Performance improvement of air source heat pump using gas-injected rotary compressor through port on blade
Affiliation:1. Department of Building Science, School of Architecture, Tsinghua University, Beijing, 100084, China;2. Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Tsinghua University, Beijing, China;1. Department of Building and Science, School of Architecture, Tsinghua University, Beijing, 100084, China;2. Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Tsinghua University, Beijing, China
Abstract:Gas injection has been a crucial technology to avoid the serious degradation of air source heat pumps in low ambient temperature. A novel injection structure on the blade for rotary compressors has been put forward in previous research to overcome the drawback of traditional injection structures. Based on a verified numerical model, the thermodynamic performance of an air source heat pump with the new gas-injected rotary compressor is investigated. The results indicate that, compared to the air source heat pump with the regular single-stage rotary compressor, the proposed injection structure can enhance heating capacity and COP of the air source heat pump by 23.1–28.2% and 4.5–8.1%, respectively.