首页 | 本学科首页   官方微博 | 高级检索  
     


Comparison of CO2 generation (BACTEC) and viable-count methods to determine the postantibiotic effect of antimycobacterial agents against Mycobacterium avium complex
Authors:GG Zhanel  MH Saunders  JN Wolfe  DJ Hoban  JA Karlowsky  AM Kabani
Affiliation:Department of Medical Microbiology and Faculty of Pharmacy, University of Manitoba, Health Sciences Centre, Winnipeg, Canada. ggzhanel@pcs.mb.ca
Abstract:The postantibiotic effects (PAEs) of antimycobacterial agents determined with a BACTEC TB-460 instrument (CO2 production) and by a traditional viable-count method against Mycobacterium avium complex (MAC) were not significantly different (P > 0.05). The longest PAEs following a 2-h exposure to 2x the MIC were induced by amikacin (10.3 h), rifampin (9.7 h), and rifabutin (9.5 h), while the shortest PAEs resulted from clofazimine (1.7 h) and ethambutol (1.1 h) exposure. CO2 generation is a valid and efficient means of determining in vitro PAEs against MAC.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号