首页 | 本学科首页   官方微博 | 高级检索  
     

西式快餐用煎炸油质量近红外快速检测模型的建立
引用本文:胡明明,张权,宁舒娴,吴思纷,张国文,胡兴.西式快餐用煎炸油质量近红外快速检测模型的建立[J].食品工业科技,2022,43(11):11-17.
作者姓名:胡明明  张权  宁舒娴  吴思纷  张国文  胡兴
作者单位:1.江西师范大学国家淡水鱼加工技术研发专业中心,江西南昌 3300222.江西师范大学生命科学院,江西南昌 3300223.南昌大学食品科学与技术国家重点实验室,江西南昌 330047
基金项目:国家自然科学青年基金项目(31801470);江西省教育厅科学技术研究项目(GJJ210322);江西省青年科学基金项目(20192BAB214011)。
摘    要:为对西式快餐用煎炸油质量进行快速监测,选用近红外光谱法(NIRS)联合偏最小二乘法(PLS),分别建立酸价和极性组分两个煎炸油质量指标的定量模型。结果表明,酸价和极性组分的定标模型校正决定系数(R2)均为0.9974,校正标准差均方根(RMSEC)分别为0.111和0.359,预测标准差均方根(RMSEP)分别为0.171和0.562。盲样验证、精密度及准确度分析结果显示,酸价和极性组分的NIR预测值同真实值的相关方程的相关系数分别为0.9944、0.9761,应用所建模型预测同一煎炸油样品的酸价和极性组分的相对标准偏差(RSD)分别为0.934%和1.278%,表明所建模型对煎炸油样品的酸价和极性组分预测能力较好,且有较好的重现性。因此,基于近红外光谱定量模型,可以对西式快餐用煎炸油质量进行快速、准确地监测。

关 键 词:煎炸油    近红外光谱    酸价    极性组分
收稿时间:2021-12-20

Study on Quick Test Model for the Quality of Frying Oil from Western-style Fast Food Restaurants by Near Infrared Spectroscopy
HU Mingming,ZHANG Quan,NING Shuxian,WU Sifen,ZHANG Guowen,HU Xing.Study on Quick Test Model for the Quality of Frying Oil from Western-style Fast Food Restaurants by Near Infrared Spectroscopy[J].Science and Technology of Food Industry,2022,43(11):11-17.
Authors:HU Mingming  ZHANG Quan  NING Shuxian  WU Sifen  ZHANG Guowen  HU Xing
Affiliation:1.National R & D Center for Freshwater Fish Processing, Jiangxi Normal University, Nanchang 330022, China2.College of Life Science, Jiangxi Normal University, Nanchang 330022, China3.State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
Abstract:In order to quickly detect the quality of frying oil from western-style fast food restaurants, calibration models of acid value and total polar compounds were established using near infrared spectroscopy (NIRS) combined with partial least squares (PLS) to evaluate the frying oil quality. The findings presented that the correction coefficient of calibration model of acid value and total polar compounds were both 0.9974. The root mean square error of cross-validation (RMSEC) were 0.111 and 0.359, respectively. The root mean square error of prediction (RMSEP) were 0.171 and 0.562, respectively. The results of blind samples verification showed that the correlation coefficients between prediction value and true value for acid value and total polar compounds of frying oil were 0.9944 and 0.9761, respectively; the precision test showed that the relative standard deviations (RSD) of acid value and total polar components using the calibration models for the same frying oil sample were 0.934% and 1.278%, respectively, which indicated that the models of quantitative analysis of acid value and total polar compounds of frying oils were good with excellent prediction abilities and reproducibility. Therefore, the rapid detection model based on near infrared spectroscopy could rapidly and accurately detect the quality of frying oil from western-style fast food restaurants.
Keywords:
点击此处可从《食品工业科技》浏览原始摘要信息
点击此处可从《食品工业科技》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号