首页 | 本学科首页   官方微博 | 高级检索  
     


Preparation of microporous layer for proton exchange membrane fuel cell by using polyvinylpyrrolidone aqueous solution
Authors:Shuchun Yu  Xiaojin Li  Jinkai Hao  Sa Liu  Zhigang Shao  Baolian Yi
Affiliation:1. Fuel Cell System and Engineering Laboratory, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian 116023, China;2. University of Chinese Academy of Sciences, Beijing 100039, China
Abstract:A new method of preparing microporous layer (MPL) for proton exchange membrane fuel cell (PEMFC) was presented in this paper. Considering the bad dispersion of PTFE aqueous suspension in the carbon slurry based on ethanol, polyvinylpyrrolidone (PVP) aqueous solution was used to prepare carbon slurry for microporous layer. The prepared gas diffusion layers (GDLs) were characterized by scanning electron microscopy, contact angle system and pore size distribution analyzer. It was found that the GDL prepared with PVP aqueous solution had higher gas permeability, as well as more homogeneous hydrophobicity. Moreover, the prepared GDLs were used in the cathode of fuel cell and evaluated with fuel cell performance and EIS analysis, and the GDL prepared with PVP aqueous solution indicated better fuel cell performance and lower ohmic resistance and mass transfer resistance.
Keywords:Proton exchange membrane fuel cell   Gas diffusion layer   Polytetrafluoroethylene   Carbon slurry