Preparation of microporous layer for proton exchange membrane fuel cell by using polyvinylpyrrolidone aqueous solution |
| |
Authors: | Shuchun Yu Xiaojin Li Jinkai Hao Sa Liu Zhigang Shao Baolian Yi |
| |
Affiliation: | 1. Fuel Cell System and Engineering Laboratory, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian 116023, China;2. University of Chinese Academy of Sciences, Beijing 100039, China |
| |
Abstract: | A new method of preparing microporous layer (MPL) for proton exchange membrane fuel cell (PEMFC) was presented in this paper. Considering the bad dispersion of PTFE aqueous suspension in the carbon slurry based on ethanol, polyvinylpyrrolidone (PVP) aqueous solution was used to prepare carbon slurry for microporous layer. The prepared gas diffusion layers (GDLs) were characterized by scanning electron microscopy, contact angle system and pore size distribution analyzer. It was found that the GDL prepared with PVP aqueous solution had higher gas permeability, as well as more homogeneous hydrophobicity. Moreover, the prepared GDLs were used in the cathode of fuel cell and evaluated with fuel cell performance and EIS analysis, and the GDL prepared with PVP aqueous solution indicated better fuel cell performance and lower ohmic resistance and mass transfer resistance. |
| |
Keywords: | Proton exchange membrane fuel cell Gas diffusion layer Polytetrafluoroethylene Carbon slurry |