首页 | 本学科首页   官方微博 | 高级检索  
     

高压煤粉锅炉过热器爆管原因分析
引用本文:徐启明. 高压煤粉锅炉过热器爆管原因分析[J]. 大氮肥, 2013, 0(1): 42-44
作者姓名:徐启明
作者单位:中国石化湖北化肥分公司
摘    要:针对2台WG240-10.3/2型高压煤粉锅炉过热器多次爆管的问题,对爆管原因进行分析,认为四角切圆燃烧器残余旋流、蒸汽流量偏差、管内汽流阻力不均及三次风带粉过多是促使过热器爆管的重要原因。

关 键 词:过热器  爆管  残余旋流  烟温偏差

ANALYSIS OF CAUSE ON TUBE BURST IN SUPERHEATER OF HIGH PRESSURE PULVERIZED COAL BOILER
Xu Qiming. ANALYSIS OF CAUSE ON TUBE BURST IN SUPERHEATER OF HIGH PRESSURE PULVERIZED COAL BOILER[J]. Large Scale Nitrogenous Fertilizer Industry, 2013, 0(1): 42-44
Authors:Xu Qiming
Affiliation:Xu Qiming(Sinopec Hubei Chemical Fertilizer Branch,Zhijiang 443200)
Abstract:Some important reasons for tube burst are found with respect of two(2) WG240-10.3/2 high pressure pulverized coal boiler superheater,such as residual swirl in tangential firing boiler,steam flow offset,uneven steam flow resistance in the tube,and excess powder entrained in tertiary air.
Keywords:superheater  tube burst  residual swirl  offset of flue gas temperature
本文献已被 CNKI 维普 等数据库收录!