A study of natural circulation in the evaporator of a horizontal-tube heat recovery steam generator |
| |
Authors: | P. V. Roslyakov K. A. Pleshanov K. V. Sterkhov |
| |
Affiliation: | 1. Moscow Power Engineering Institute National Research University, Krasnokazarmennaya ul. 14, Moscow, 111250, Russia
|
| |
Abstract: | ![]() Results obtained from investigations of stable natural circulation in an intricate circulation circuit with a horizontal layout of the tubes of evaporating surface having a negative useful head are presented. The possibility of making a shift from using multiple forced circulation organized by means of a circulation pump to natural circulation in vertical heat recovery steam generator is estimated. Criteria for characterizing the performance reliability and efficiency of a horizontal evaporator with negative useful head are proposed. The influence of various design solutions on circulation robustness is considered. With due regard of the optimal parameters, the most efficient and least costly methods are proposed for achieving more stable circulation in a vertical heat recovery steam generator when a shift is made from multiple forced to natural circulation. A procedure for calculating the circulation parameters and an algorithm for checking evaporator performance reliability are developed, and recommendations for the design of heat recovery steam generator, nonheated parts of natural circulation circuit, and evaporating surface are suggested. |
| |