首页 | 本学科首页   官方微博 | 高级检索  
     

基于Lyot滤波器和长周期光纤光栅的温度与应变的同时测量
引用本文:童峥嵘,郭阳,杨秀峰,曹晔.基于Lyot滤波器和长周期光纤光栅的温度与应变的同时测量[J].中国激光,2012,39(3):305002-126.
作者姓名:童峥嵘  郭阳  杨秀峰  曹晔
作者单位:童峥嵘:天津理工大学薄膜电子与通信器件重点实验室, 天津 300384
郭阳:天津理工大学薄膜电子与通信器件重点实验室, 天津 300384
杨秀峰:天津理工大学薄膜电子与通信器件重点实验室, 天津 300384
曹晔:天津理工大学薄膜电子与通信器件重点实验室, 天津 300384
基金项目:国家自然科学基金(61107052) 资助课题。
摘    要:提出了一种基于光纤干涉原理的同时测量温度和应变的传感器,通过在Lyot滤波器(LFF)中熔接一段长周期光纤光栅(LPFG)构成。其中LFF由在起偏器(PL1)和检偏器(PL2)中嵌入一段保偏光纤(PMF)构成。实验结果表明,LFF的干涉谱和LPFG的谐振峰对温度和应变有不同的响应灵敏度,因此可利用敏感矩阵实现对温度和应变的同时测量。实验测得LFF和LPFG的温度灵敏度分别为-1.3173nm/℃和0.0604nm/℃,应变灵敏度分别为-0.0185nm/με和-0.0004nm/με。温度和应变的测量精度分别为±1℃和±25με。该系统采用线性结构,结构简单、易于实现,具有较高的灵敏度和稳定性,同时测量结果具有良好的线性度。

关 键 词:光纤光学  长周期光纤光栅  Lyot滤波器  同时测量  悬臂梁
收稿时间:2011/9/20

Simultaneous Measurement of Temperature and Strain Based on a Long-Period Fiber Grating Combined with a Lyot Fiber Filter in a Linear Configuration
Tong Zhengrong Guo Yang Yang Xiufeng Cao Ye.Simultaneous Measurement of Temperature and Strain Based on a Long-Period Fiber Grating Combined with a Lyot Fiber Filter in a Linear Configuration[J].Chinese Journal of Lasers,2012,39(3):305002-126.
Authors:Tong Zhengrong Guo Yang Yang Xiufeng Cao Ye
Affiliation:Tong Zhengrong Guo Yang Yang Xiufeng Cao Ye(Key Laboratory of Film Electronics and Communication Devices,Tianjin University of Technology,Tianjin 300384,China)
Abstract:A novel sensor for simultaneous temperature and strain measurement based on fiber interference is proposed. The sensor is formed by incorporating a long-period fiber grating (LPFG) inside a Lyot fiber filter (LFF), in which the LFF can be constructed by placing a polarization maintaining fiber (PMF) between two polarizers (PL) with the primary axis of the fiber rotated 45° relative to the polarizer axes. Due to the different responses of the LFF and LPFG to temperature and strain variations, it is possible for the proposed fiber sensor to measure temperature and strain simultaneously by use of a well-conditioned sensitivity matrix equation. The experimental temperature sensitivity coefficients of LFF and LPFG are -1.3173 nm/℃ and 0.0604 nm/℃, respectively. The strain sensitivity coefficients achieve -0.0185 nm/με and -0.0004 nm/με, respectively. A sensing resolution of ±1 ℃ in temperature and ±25 με in strain has been experimentally obtained. The experimental results are in good agreement with the theoretical analysis. Furthermore, this linear configuration is simple and easy to achieve, and has high stability and sensitivity.
Keywords:fiber optics  long-period fiber grating  Lyot fiber filter  simultaneous measurement  cantilever beam
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号