对水电厂事故低油压引起紧急停机的分析与处理
引用本文:魏加富,邹桂丽,王辉斌.对水电厂事故低油压引起紧急停机的分析与处理[J].湖北水力发电,2014(4):56-57,67.
作者姓名:魏加富  邹桂丽  王辉斌
作者单位:国网湖南省电力公司电力科学研究院,湖南长沙410007
摘    要:介绍某水电厂6号机并入小网运行时,因电压波动使调速器油压装置油泵故障不能自启动,导致调速器事故低油压水机主保护和后备保护动作,引起机组紧急停机,进水口闸门紧急关闭。对事件发生前后的相关数据进行了分析,对电站暴露出的问题提出了具体的解决措施。

关 键 词:水电厂  油压装置  事故低油压  小网运行

Analysis and Treatment of Emergency Shutdown Caused by Tripping Lower Oil Pressure in A Hydropower Station
WEI Jiafu,ZOU Guili,WANG Huibin.Analysis and Treatment of Emergency Shutdown Caused by Tripping Lower Oil Pressure in A Hydropower Station[J].Hubei Water Power,2014(4):56-57,67.
Authors:WEI Jiafu  ZOU Guili  WANG Huibin
Abstract:An accident of emergency shutdown of a power generating unit and disclosure of the inlet gate is described . When the generator is synchronized to the small power grid , the oil pressure pump in the speed control system cannot be launched because of the voltage fluctuation , which leads the main and backup protection actions of the unit by tripping lower oil pressure .Relevant data before and after the accident is analyzed and detailed measures are proposed to solve the problem .
Keywords:hydropower station  oil pressure equipment  tripping lower oil pressure  small grid operation