首页 | 本学科首页   官方微博 | 高级检索  
     

U形管换热器管板隔板槽面积计算
引用本文:毕庶力,何志萍. U形管换热器管板隔板槽面积计算[J]. 石油化工设备, 2009, 38(1): 53-55
作者姓名:毕庶力  何志萍
作者单位:中油辽河工程有限公司,辽宁,盘锦,124010
摘    要:常用U形管换热器多为双管程或四管程,GB 151~1999《管壳式换热器》中给出了U形管换热器双管程管予正三角形排列和正方形排列隔板槽面积的计算公式。补充了双管程管子的另外两种排列方式以及四管程管子不同排列方式下隔板槽面积的计算公式。

关 键 词:U形管换热器  管板  隔板槽面积  计算

Calculation of Bulkhead Tank Area on Tubesheet in U-tube Heat Exchanger
BI Shuli,HE Zhi-ping. Calculation of Bulkhead Tank Area on Tubesheet in U-tube Heat Exchanger[J]. Petro-Chemical Equipment, 2009, 38(1): 53-55
Authors:BI Shuli  HE Zhi-ping
Affiliation:(China Liaohe Petroleum Engineering Co. Ltd. , Panjin 124010, China)
Abstract:There are two tube passes or four tube passes in U-tube heat exchanger. Calculation methods of bulkhead tank area for regular triangle arrangement and square arrangement was given in GB 151-1999《Tubular Heat Exchangers》. Another calculation method of bulkhead tank area of two and four tube passes for U tube heat exchanger was given.
Keywords:U-tube heat exchanger  tubesheet  bulkhead tank area  calculation
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号