首页 | 本学科首页   官方微博 | 高级检索  
     


Design and Realization of a Built-In Current Sensor for IDDQ Testing and Power Dissipation Measurement
Authors:Karim Arabi  Bozena Kaminska
Affiliation:(1) Department of Electrical Engineering, E´cole de Technologie Supe´rieure (E´TS), Montreal, QC H3C 1K3, Canada;(2) Opmaxx, Inc., Beaverton, Oregon, U.S.A.
Abstract:Built-in current sensor (BICS) is known to enhance test accuracy, defect coverage of quiescent current (IDDQ) testing method in CMOS VLSI circuits. For new deep-submicron technologies, BICSs become essential for accurate and practical IDDQ testing. This paper presents a new BICS suitable for power dissipation measurement and IDDQ testing. Although the BICS presented in this paper is dedicated to submicron technologies that require reduced supply voltage, it can also be used for applications and technologies requiring normal supply voltage. The proposed BICS has been extended for on-line measurement of the power dissipation using only an additional capacitor. Power dissipation measurement is important for safety-critical applications and battery-powered systems. A simple self-test approach to verify the functionality and accuracy of BICSs has also been introduced. The proposed BICS has been implemented and tested using an N-well CMOS 1.2 mgrm technology. Practical results demonstrate that a very good measurement accuracy can be achieved.
Keywords:IDDQ testing  BICS  power dissipation  on-line testing  voltage regulator
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号