首页 | 本学科首页   官方微博 | 高级检索  
     


Adaptive Calibration Method in Multiport Amplifier for K‐Band Payload Applications
Authors:Seong‐Mo Moon  Dong‐Hwan Shin  Hong‐yul Lee  Man‐seok Uhm  In‐Bok Yom  Moon‐Que Lee
Abstract:This letter proposes a novel calibration method for a multiport amplifier (MPA) to achieve optimum port‐to‐port isolation by correcting both the amplitude and phase of the calibration signals. The proposed architecture allows for the detection of the phase error and amplitude error in each RF signal path simultaneously and can enhance the calibrated resolution by controlling the analog phase shifters and attenuators. The designed urn:x-wiley:12256463:media:etr20718:etr20718-math-0001 and urn:x-wiley:12256463:media:etr20718:etr20718-math-0002 MPAs show isolation characteristics of 30 dB and 27 dB over a frequency range of 19.5 GHz to 22.5 GHz, respectively.
Keywords:Multiport amplifier (MPA)  phase shifter  attenuator  drive amplifier  microwave monolithic integrated circuit (MMIC)  calibration  port‐to‐port isolation