首页 | 本学科首页   官方微博 | 高级检索  
     

AlCl3水溶液的激光诱导击穿光谱研究
引用本文:王传辉,戴琳,张先燚,姚关心,季学韩,凤尔银,郑荣儿,崔执凤.AlCl3水溶液的激光诱导击穿光谱研究[J].中国激光,2006,33(9):1190-1194.
作者姓名:王传辉  戴琳  张先燚  姚关心  季学韩  凤尔银  郑荣儿  崔执凤
作者单位:1. 安徽师范大学原子与分子物理研究所,安徽,芜湖,241000
2. 中国海洋大学光学光电子实验室,山东,青岛,266071
基金项目:安徽省原子与分子物理重点学科建设基金,教育部科技研究重点项目,安徽省教育厅自然科学基金(2001KJ116ZD)资助课题
摘    要:激光诱导击穿光谱(LIBS)技术已成功地对固体样品和气相样品中的重金属痕量元素进行了定性或半定量分析。为对液体基质的重金属元素进行痕量分析,使用实验中容易实现的单脉冲激光诱导击穿光谱技术,测定了AlCl3水溶液的激光诱导击穿光谱。系统地研究了溶液中Al原子激光诱导击穿光谱信号的时间演化特性、激光能量对激光诱导击穿光谱信号的影响和激光诱导击穿光谱用于液体中AlCl3痕量分析的检测限。实验结果表明,此方法所适用的激光能量比前人所做实验的激光能量小,只需50 mJ左右,这使得实验条件更容易得到满足,同时得到了一个较高的液体样品的激光诱导击穿光谱信号检测限。实验还表明,液体激光诱导击穿光谱信号存在特有的时间演化特性,其激光诱导击穿光谱信号的寿命相对于固体样品激光诱导击穿光谱信号来说比较短,只有30 ns左右,同时激光诱导击穿光谱信号强度上升和衰减也比较迅速。

关 键 词:激光物理  时间演化特性  激光诱导击穿光谱  AlCl3溶液  检测限
收稿时间:2006/4/26

Investigation on Laser-Induced Breakdown Spectroscopy of AlCl3 Water Solution
WANG Chuan-hui,DAI Lin,ZHANG Xian-yi,YAO Guan-xin,JI Xue-han,FENG Er-yin,ZHENG Rong-er,CUI Zhi-feng.Investigation on Laser-Induced Breakdown Spectroscopy of AlCl3 Water Solution[J].Chinese Journal of Lasers,2006,33(9):1190-1194.
Authors:WANG Chuan-hui  DAI Lin  ZHANG Xian-yi  YAO Guan-xin  JI Xue-han  FENG Er-yin  ZHENG Rong-er  CUI Zhi-feng
Abstract:The laser-induced breakdown spectroscopy (LIBS) technique has been successfully employed for qualitative and semi-quantitative elemental analysis of trace heavy metal element in solid samples and gas samples.To make an analysis of the heavy metal trace element in liquid,the LIBS of the AlCl_3 solution was measured with the single pulse LIBS technique applied flexibly in experiment.The time revolution properties of the Al LIBS signal in the solution,the dependence of the LIBS signal on the laser energy,and the detection limit of the LIBS technique were also investigated.The experimental result showed that the laser energy suitable for this experiment is approximately 50 mJ and lower than that reported in previous experiments.With this easy realizable experiment,a higher detection limit of the LIBS in liquid samples was obtained.The result also showed that there are peculiar time revolution properties of the LIBS signal in liquid.The lifetime of LIBS signal in liquid samples was shorter than that in solid samples,about 30 ns.Meanwhile,the LIBS signal intensity increased and decreased quickly,only lasting several ns.
Keywords:laser physics  time revolution property  laser-induced breakdown spectroscopy  AlCl_3 solution  detection limit
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号