首页 | 本学科首页   官方微博 | 高级检索  
     

不同版本HITRAN数据库中红外波段上行传输透过率的计算
引用本文:刘丹丹,黄印博,戴聪明,魏合理,饶瑞中. 不同版本HITRAN数据库中红外波段上行传输透过率的计算[J]. 红外与激光工程, 2013, 42(7): 1776-1782
作者姓名:刘丹丹  黄印博  戴聪明  魏合理  饶瑞中
作者单位:1.中国科学院安徽光学精密机械研究所 中国科学院大气成分与光学重点实验室,安徽 合肥 230031;
摘    要:为比较不同版本数据库对透过率计算精度的影响,利用逐线积分辐射传输模式,对比分析了HITRAN 2k、HITRAN 04和HITRAN 08数据库在中红外波段(2~12 m)、四种初始高度(1、10、15、20 km)上行大气传输分子透过率的差异。结果表明,在4种初始高度上,04版本的平均绝对偏差均比2k版本小,而且在某些波段上对应的绝对偏差均较大:在1 cm-1分辨率时,仅考虑CO2吸收,04、2k版本对应的最大绝对偏差为0.338(2.696 m)和0.394(2.749 m);在0.1 cm-1分辨率时,考虑7种分子吸收,04、2k版本对应的最大绝对偏差达到了0.95(4.191 m)和0.936(3.568 m)。在计算中红外波段不同初始高度上行大气传输透过率时,采用旧版本的HITRAN数据库在某些波段会产生相当大的误差。

关 键 词:LBLRTM   大气透过率   HITRAN数据库   绝对偏差
收稿时间:2012-11-02

Effect of changes of HITRAN database on transmittance calculation in mid-infrared region along vertical uplink
Liu Dandan , Huang Yinbo , Dai Congming , Wei Heli , Rao Ruizhong. Effect of changes of HITRAN database on transmittance calculation in mid-infrared region along vertical uplink[J]. Infrared and Laser Engineering, 2013, 42(7): 1776-1782
Authors:Liu Dandan    Huang Yinbo    Dai Congming    Wei Heli    Rao Ruizhong
Affiliation:1.Key Laboratory of Atmospheric Composition and Optical Radiation,Anhui Institute of Optics and Fine Mechanics,Chinese Academy of Sciences,Hefei 230031,China;2.University of Chinese Academy of Sciences,Beijing 100049,China
Abstract:The mid-infrared atmospheric transmittance and the absolute deviation were calculated with three different HITRAN databases using LBL software. Results show that the average absolute deviation of HITRAN2k and HITRAN04 decreases with the increase of initial height, the absolute deviation of HITRAN2k and HITRAN04 increases as the resolution increases. The average absolute deviation of HITRAN04 was less than the HITRAN2k at the four initial height. For example, the maximum absolute deviation of HITRAN04 and HITRAN2k was 0.338 and 0.394 with 1 cm-1 spectral resolution only considering the absorption of CO2. The maximum absolute deviation of HITRAN04 and HITRAN2k was 0.950 and 0.936 with 0.1 cm-1 spectral resolution considering the absorption of all kinds molecules. The deviation caused by old versions of the database should be considered for calculating infrared atmospheric transmittance. The difference caused by different versions of the database and spectral resolution should be considered for calculating infrared atmospheric transmittance.
Keywords:LBL software  atmosphere transmittance  HITRAN database  absolute deviation
本文献已被 万方数据 等数据库收录!
点击此处可从《红外与激光工程》浏览原始摘要信息
点击此处可从《红外与激光工程》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号