首页 | 本学科首页   官方微博 | 高级检索  
     

Optical readout uncooled infrared imaging detector using knife-edge filter operation
作者单位:ZHANG Q(Key Laboratory of Mechanical Behavior and Design of Materials, University of Science and Technology of China, Hefei 230027, China) ; MIAO Z(Key Laboratory of Mechanical Behavior and Design of Materials, University of Science and Technology of China, Hefei 230027, China) ; GUO Z(Key Laboratory of Mechanical Behavior and Design of Materials, University of Science and Technology of China, Hefei 230027, China) ; DONG F(Key Laboratory of Mechanical Behavior and Design of Materials, University of Science and Technology of China, Hefei 230027, China) ; XIONG Z(Key Laboratory of Mechanical Behavior and Design of Materials, University of Science and Technology of China, Hefei 230027, China) ; WU X(Key Laboratory of Mechanical Behavior and Design of Materials, University of Science and Technology of China, Hefei 230027, China) ; CHEN D(Institute of Microelectronics Chinese Academy of Science, Beijing 100029, China) ; LI C(Institute of Microelectronics Chinese Academy of Science, Beijing 100029, China) ; JIAO B(Institute of Microelectronics Chinese Academy of Science, Beijing 100029, China) ;
基金项目:国家自然科学基金;国家重点基础研究发展计划(973计划)
摘    要:An optical readout uncooled infrared (IR) imaging detector of bimaterial cantilever array using knife-edge filter operation (KEFO) is demonstrated. The angle change of each cantilever in a focal plane array (FPA) can be simultaneously detected with a resolution of 10-5 degree. A deformation magnifying substrate-free micro-cantilever unit with multi-fold interval metallized legs is specially designed and modeled. A FPA with 160×160 pixels is fabricated and thermal images with noise equivalent temperature difference (NETD) of 400 mK are obtained by this imaging detector.

关 键 词:光学读出  非制冷红外成象探测器  刀口滤波器运算  设计  模型
文章编号:1673-1905(2007)02-0119-04
收稿时间:9 January 2007

Optical readout uncooled infrared imaging detector using knife-edge filter operation
Authors:Zhang Q  Miao Z  Guo Z  Dong F  Xiong Z  Wu X  Chen D  Li C and Jiao B
Affiliation:(1) Key Laboratory of Mechanical Behavior and Design of Materials, University of Science and Technology of China, Hefei, 230027, China;(2) Institute of Microelectronics Chinese Academy of Science, Beijing, 100029, China
Abstract:An optical readout uncooled infrared (IR) imaging detector of bimaterial cantilever array using knife-edge filter operation(KEFO) is demonstrated. The angle change of each cantilever in a focal plane array (FPA) can be simultaneously detected with a resolution of 10-5 degree. A deformation magnifying substrate-free micro-cantilever unit with multi-fold interval metallized legs is specially designed and modeled. A FPA with 160× 160 pixels is fabricated and thermal images with noise equivalent temperature difference (NETD) of 400 mK are obtained by this imaging detector.
Keywords:TP206+  1
本文献已被 CNKI 万方数据 SpringerLink 等数据库收录!
点击此处可从《光电子快报》浏览原始摘要信息
点击此处可从《光电子快报》下载全文