首页 | 本学科首页   官方微博 | 高级检索  
     


Stereo imaging quality evaluation in a full-color three-dimensional display system
Authors:DUAN Wei  SANG Xin-zhu  YU Xun-bo  GAO Xin  CHEN Zhi-dong  WANG Yue  YAN Bin-bin  YUAN Jin-hui  WANG Kui-ru  YU Chong-xiu  DOU Wen-hua and XIAO Li-quan
Affiliation:State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876, China;State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876, China;State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876, China;State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876, China;State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876, China;State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876, China;State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876, China;State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876, China;State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876, China;State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876, China;School of Computer Science, National University of Defense Technology, Changsha 410073, China;School of Computer Science, National University of Defense Technology, Changsha 410073, China
Abstract:To evaluate the light field display system with a liquid crystal display (LCD) and a holographic functional screen (HFS), the voxel theory based on the ray tracing is used. By analyzing the voxels defined by the cases of corresponding pixels overlapping completely and partially in the image space, the resolution characteristics of the system are discussed. The theoretical model is verified in the reconstruction experiment of a resolution target and compared with the calculation result of the presented system. Finally, we give an optimization method for the display image quality.
Keywords:
本文献已被 SpringerLink 等数据库收录!
点击此处可从《光电子快报》浏览原始摘要信息
点击此处可从《光电子快报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号