首页 | 本学科首页   官方微博 | 高级检索  
     

汽轮机高调门阀杆断裂故障的改造优化探索
引用本文:李登峰.汽轮机高调门阀杆断裂故障的改造优化探索[J].冶金动力,2010(1):46-47,50.
作者姓名:李登峰
作者单位:济南钢铁集团公司能源动力厂,山东济南,250101
摘    要:通过对济钢燃气-蒸汽联合循环发电系统40MW汽轮机高调门阀杆疲劳损坏故障分析,提出在低负荷时阀碟处于不稳定状态,气流冲击和气流振荡加剧阀杆损坏的观点。依据故障原理有针对性的提出改造措施,在设备运行状态和高调门结构方面实施优化改造,顺利解决了故障问题。

关 键 词:高调门  阀杆  脱落  损坏  气流振荡

Fracture Fault Analysis and Reconstruction of Pole of High Pressure Control Valve for Turbine
LI Deng-feng.Fracture Fault Analysis and Reconstruction of Pole of High Pressure Control Valve for Turbine[J].Metallurgical Power,2010(1):46-47,50.
Authors:LI Deng-feng
Affiliation:LI Deng-feng(Energy Sources and Power Plant,Jigang Group Co.,Ltd.,Jinan,Shandong 250101,China)
Abstract:Through analysis of fatigue damage fault of pole of high pressure control valve for 40MW turbine in the gas-steam cycle generation system of Jigang Group Co.,Ltd,it was found out that valve discs were unstable in low load,therefore,air flow impact and air flow vibration oc-curred,resulting in quick damage of the valve pole.According to fault cause,the relevant recon-struction measures were given.An optimization reconstruction was made in turbine running and on structure of the valve,which solved the fault successfully.
Keywords:high pressure controlvalve  valve pole  drop-out  damage  air flow vibration