电感耦合等离子体发射光谱法测定锡钛合金中钛含量 |
| |
引用本文: | 王晓艳,禄妮,张磊,李波.电感耦合等离子体发射光谱法测定锡钛合金中钛含量[J].钛工业进展,2009,26(6):42-43. |
| |
作者姓名: | 王晓艳 禄妮 张磊 李波 |
| |
作者单位: | 西北有色金属研究院,陕西,西安,710016 |
| |
摘 要: | 提出了电感耦合等离子体发射光谱仪(ICP-AES)测定锡钛合金中钛含量的分析方法。讨论了分析线、酸度及基体元素对钛测定结果的影响。对样品进行连续9次测定,其相对标准偏差在0.47%-0.51%区间内,回收率在98.1%~102.8%之间。该法快捷、准确,并且克服了化学分析方法的过程繁琐、周期长、工作量大等缺点。
|
关 键 词: | 电感耦合等离子体发射光谱法 锡钛合金 钛 |
Determination of Titanium in Tin and Titanium Alloy by ICP-AES |
| |
Authors: | Wang Xiaoyan Lu Ni Zhang Lei Li Bo |
| |
Affiliation: | ( Northwest Institute for Nonferrous Metal Research, Xi'an 710016, China) |
| |
Abstract: | Determination of titanium content in tin and titanium alloy was studied using the whole spectrum direct-reading high-resolution inductively coupled plasma atomic emission spectrometer (ICP-AES). The effects of the analysis line, acidity and matrix elements on determination of titanium were analyzed. The relative standard deviation was from 0. 47% to 0. 51%, and the recovery rate was between 98.1% and 102. 8% by 9-time sample analysis. |
| |
Keywords: | ICP-AES tin and titanium alloy titanium |