首页 | 本学科首页   官方微博 | 高级检索  
     

主换热器热端温差过大的故障分析及处理
引用本文:覃盼,陈先亮,吴建军.主换热器热端温差过大的故障分析及处理[J].有色冶金设计与研究,2013(6):38-40.
作者姓名:覃盼  陈先亮  吴建军
作者单位:中金岭南丹霞冶炼厂,广东韶关512325
摘    要:针对在空分设备运行过程中主换热器热端温差过大的现象,从换热介质和热端温差变化阶段的系统运行情况入手,分析了热端温差过大的原因,用压缩空气从下塔对换热器至分子筛吸附器出口之间管道进行反吹,排除了故障,空分系统投入正常运行。

关 键 词:制氧车间  主换热器  热端温差  反吹  空分系统  分子筛吸附器

Fault Analysis and Treatment of Main Heat Exchanger Owing to Large Hot End Temperature Difference
Authors:QIN Pan  CHEN Xian-liang  WU Jian-jun
Affiliation:(Danxia Smelter of Zhongjin Lingnan Nonfemet Co.,Ltd., Shaoguan, Guangdong 512325, China)
Abstract:Aiming at the phenomena of large temperature difference of main heat exchanger hot end during the operation of air separation equipment, the paper analyzes the reason of large temperature difference of hot end from the aspect of heat exchange medium and condition of system operation at hot end temperature difference change phase, compressed air is used for back flushing from lower tower to pipeline between heat exchanger and outlet of molecular sieve adsorber, by which the fault is removed, and air senaration svstem will be nut into normal oneration.
Keywords:oxygen making plant  main heat exchanger  hot end temperature difference  back flushing  air separation system  molecular sieve adsorber