压力容器测厚值异常的原因及应对措施
引用本文:邢国强,张广兴.压力容器测厚值异常的原因及应对措施[J].金属材料与冶金工程,2009,37(4):54-56.
作者姓名:邢国强  张广兴
作者单位:河北省电力研究院,河北,石家庄,050021
摘    要:在对压力容器的检验过程中,经常会出现大量超声测厚值示值失真现象,从而造成错误的结论和处理,甚至可能引发事故。据此,对其进行了详细分析,提出了相应的解决方法。

关 键 词:超声波测厚  示值异常  压力容器  措施

Reasons and Countermeasures of the Abnormal Measuring Thickness Values for Pressure Vessel
ZING Guo-qiang,ZHANG Guang-xing.Reasons and Countermeasures of the Abnormal Measuring Thickness Values for Pressure Vessel[J].Metal Materials And Metallurgy Engineering,2009,37(4):54-56.
Authors:ZING Guo-qiang  ZHANG Guang-xing
Affiliation:Hebei Electric Power Research Institute;Shijiazhuang 050021;China
Abstract:In the inspection process to pressure vessel,the distortion phenomenon for a large number of ultrasonic measuring thickness values takes place frequently,thereby,results in erroneous conclusions and to deal with,and may even lead to accidents.In view of the above,analyzes in detail these questions and proposes corresponding solving means.
Keywords:ultrasonic measuring thickness  showed abnormal values  pressure vessel  measures  