摘    要:利用电场与渗流场控制方程及边界条件相似的原理,对含缺陷的防渗土工膜上的电位分布进行有限元模拟,获得缺陷附近的电位分布特征,进而判断缺陷位置。此外,对电极埋设位置、施加电压值和探测间距等因素进行敏感性分析。计算结果表明:双电极法可有效确定土工膜缺陷位置,土工膜缺陷越靠近励磁电源电极,越有利于缺陷的准确探测;沿着缺陷中心线方向进行探测,可高效探测缺陷位置;移动探测仪的电极间距应以探测长度的5%~10%为宜。研究成果对双电极法用于土工膜缺陷探测有理论指导意义。

关 键 词:土工膜  缺陷探测  电极位置  探测间距  数值模拟
收稿时间:2017-07-10
修稿时间:2017-08-04

Numerical Simulation of Defect Detection of Geomembrane Based on Dual-electrode Method
CEN Wei-jun,LUO Jia-rui,DU Xu-huang,HE Hao-nan,GENG Li-yan.Numerical Simulation of Defect Detection of Geomembrane Based on Dual-electrode Method[J].Journal of Yangtze River Scientific Research Institute,2019,36(2):97-100.
Authors:CEN Wei-jun  LUO Jia-rui  DU Xu-huang  HE Hao-nan  GENG Li-yan
Affiliation:1.College of Water Conservancy and Hydropower Engineering, Hohai University, Nanjing 210098, China;2.Research Center on Embankment Safety and Disaster Prevention Engineering Technology, Ministry of Water Resources, Zhengzhou 450003,China;3.The Second Design and Research Institute of Water Conservancy and Hydropower of Hebei Province, Shijiazhuang 050021, China
Abstract:In the light of the similarity of governing equation and boundary condition between electric field and seepage field, the potential distribution on the surface of defective impermeable geomembrane was simulated via finite element approach. The anomaly potential distributions in the vicinity of defect were obtained to determine the location of defect. In addition, sensitivity analysis of the buried position of electrode, excitation voltage, and dipole spacing were taken into account. The computed results demonstrate that the defect in the geomembrane can be accurately located by using pole-dipole electrical survey methods. The detection of defect is more effective for a closer distance between the defect and the electrode; the detection efficiency can be increased when the detective line is along the center line of defect. The results also show that the dipole spacing of 5%-10% of the length of survey line is appropriate for detecting the defect in geomembrane. The calculated results are of theoretical guiding significance for the application of pole-dipole electrical survey methods to the detection of geomembrane defect.
Keywords:geomembrane  defect detection  location of electrode  detection distance  numerical simulation  
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《长江科学院院报》浏览原始摘要信息
点击此处可从《长江科学院院报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号