首页 | 本学科首页   官方微博 | 高级检索  
     

考虑接触行为的U型渠道冻胀数值模拟
引用本文:高凤,娄宗科,肖旻.考虑接触行为的U型渠道冻胀数值模拟[J].长江科学院院报,2020,37(1):161-165.
作者姓名:高凤  娄宗科  肖旻
作者单位:1.陕西省建筑职工大学,西安 710043; 2.西北农林科技大学 水利与建筑工程学院, 陕西 杨凌 712100
基金项目:十二五国家科技支撑计划项目(2012BAD08B01);十三五国家重点研发计划项目(2016YFC0400203)
摘    要:U型衬砌渠道具有良好的整体性和冻胀适应性,但在冬季仍极易因土体冻胀而导致破坏。考虑渠基冻土与衬砌接触面冻结的非线性特性和冻土、混凝土材料的塑性特征,建立能分析渠道基土与衬砌间挤压、脱开及滑移等接触力学行为的渠道冻胀破坏热力耦合数值模型。以宝鸡峡灌区塬下北干渠为原型渠道,按照模型是否考虑接触分别进行冻胀数值模拟,并对模拟结果进行对比分析。结果表明:考虑接触的模型模拟结果与原型实测值更相符,更能合理地解释U型渠道冻胀在渠底与阴坡衔接处冻胀量最小;考虑接触的混凝土塑性应变最大值是不考虑接触时的3.76倍;考虑接触的法向冻胀力和切向冻结力更均匀,最大值均减少1.5~3.0倍,应力集中现象减弱,更能反映混凝土衬砌板与渠基土之间的滑移变形与破坏准则的相互作用。研究结果为U型衬砌渠道冻胀破坏规律提供了分析方法。

关 键 词:U型渠道  冻土工程  冻胀破坏  数值模拟  接触力学行为  宝鸡峡灌区塬下北干渠  
收稿时间:2018-09-19

Numerical Simulation of Frost Heave Damage of U-shaped Canal Considering Interaction between Concrete Lining Board and Soil
GAO Feng,LOU Zong-ke,XIAO Min.Numerical Simulation of Frost Heave Damage of U-shaped Canal Considering Interaction between Concrete Lining Board and Soil[J].Journal of Yangtze River Scientific Research Institute,2020,37(1):161-165.
Authors:GAO Feng  LOU Zong-ke  XIAO Min
Affiliation:1.Architecture Zabor University of Shaanxi Province, Xi’an 710043, China; 2.College of WaterResources and Architectural Engineering, Northwest A & F University, Yangling 712100, China
Abstract:The lining structure of U-shaped canal has favorable integrity and adaptability to frost heave damage; but in winter these canals are still at high risk of frost heave damage. In consideration of the non-linear characteristic of the interface between foundation frost soil and concrete lining as well as the plasticity of frozen soil and concrete lining, we put forward a thermo-mechanical coupling numerical model for U-shaped lining canal, through which the contact mechanical behavior between the foundation and concrete lining such as squeezing, separation and glide can be analyzed. By taking Yuanxiabei main canal in Baojixia irrigation district as prototype canal, we simulated the frost heave damage of the canal in two conditions (considering and not considering the contact between foundation and lining). Results unveil that the simulation results of the model considering the contact are more consistent with the measured values of the prototype, and better explains that the frost heave of U-shaped channel is the smallest at the junction of the channel bottom and the shady slope. The maximum plastic strain of concrete with contact is 3.76 times that without contact. In addition, the normal frost heave force and tangential freeze force considering contact are more uniform, with the maximum values reducing by 1.5~3.0 times. Stress concentration is weakened, which better reflects the interaction between the slip deformation and failure criteria between the concrete lining slab and the canal foundation soil.
Keywords:U-shaped lining structure  frozen soil engineering  frost heave damage  numerical simulation  mechanical behavior in contact  Yuanxiabei canal in Baojixia irrigation district  
本文献已被 CNKI 等数据库收录!
点击此处可从《长江科学院院报》浏览原始摘要信息
点击此处可从《长江科学院院报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号