首页 | 本学科首页   官方微博 | 高级检索  
     

泗阳泵站出水流道可行性方案对比分析研究
引用本文:蒋红梅,陈松山,何钟宁.泗阳泵站出水流道可行性方案对比分析研究[J].水利与建筑工程学报,2011,9(1):104-109,136.
作者姓名:蒋红梅  陈松山  何钟宁
作者单位:扬州大学能源与动力工程学院;扬州大学水利科学与工程学院;
摘    要:结合泗阳泵站已有土建结构,采用雷诺平均纳维-斯托克斯方程(RANS)和标准k-ε湍流模型,运用SIMPLEC算法,设计虹吸式出水流道、直管式出水流道及钟形出水流道3种可行性方案.分别在流道进口未设置环量和设置环量的情况下,数值模拟3种流道内流场,预测流道内的不良流态形式及出现位置,分析各方案流道进口断面、中间断面及出口...

关 键 词:泗阳泵站  出水流道  数值模拟  对比分析研究

Comparative Analysis and Research on Feasible Schemes for Outlet Conduit of Siyang Pumping Station
JIANG Hong-mei,CHEN Song-shan,HE Zhong-ning.Comparative Analysis and Research on Feasible Schemes for Outlet Conduit of Siyang Pumping Station[J].Journal of Water Resources Architectural Engineering,2011,9(1):104-109,136.
Authors:JIANG Hong-mei  CHEN Song-shan  HE Zhong-ning
Affiliation:JIANG Hong-mei1,CHEN Song-shan1,HE Zhong-ning2(1.College of Energy and Power Engineering,Yangzhou University,Yangzhou,Jiangsu 225009,China,2.College of Hydraulic Science and Engineering,China)
Abstract:Combined with Siyang Pumping Station's existing civil structure,Reynolds-averaged Navier-Stokes(RANS) equation is applied for designing three feasible schemes of siphon outlet conduit,straight outlet conduit and bell-like outlet conduit.The standard k-ε turbulence model and SIMPLEC algorithm are also adopted in the calculation.In cases of setting the circulation and not setting the circulation in conduit intakes,the inner flow status and various types of vortices and their locations are predicted in three outlet conduits.The law of velocity distribution is analyzed on the intake section,middle section and outlet section of each scheme.In addition,the hydraulic losses and flow-cutoff methods are compared and analyzed.The calculation results show that the siphon outlet conduit's hydraulic losses are 13.1 cm and 13.9 cm,and the energy recovery rate could reach 89.78% and 89.11% in the designed conditions.Considering the hydraulic performances,it is demonstrated that three schemes are all applicable to Siyang Pumping Station and the siphon outlet conduit has better performance than the other two.
Keywords:Siyang Pumping Station  outlet conduit  numerical simulation  comparative analysis and research  
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号