首页 | 本学科首页   官方微博 | 高级检索  
     

德士古气化炉炉壁超温原因分析及相应解决措施
引用本文:张洪涛,臧庆安.德士古气化炉炉壁超温原因分析及相应解决措施[J].山东化工,2011,40(10):68-71,75.
作者姓名:张洪涛  臧庆安
作者单位:神华集团有限责任公司,北京,100011
摘    要:借鉴于国内德士古气化炉的运行实践,全面分析、总结了引起炉壁超温的各种现象和原因,针对不同原因提出了相应的解决措施。

关 键 词:德士古气化炉  炉壁超温  原因  措施

Analysis of the Causes of Overheating on the Texaco Gasifier Wall and the Corresponding Solutions
ZHANG Hong-tao,ZANG Qing-an.Analysis of the Causes of Overheating on the Texaco Gasifier Wall and the Corresponding Solutions[J].Shandong Chemical Industry,2011,40(10):68-71,75.
Authors:ZHANG Hong-tao  ZANG Qing-an
Affiliation:ZHANG Hong - tao , ZANG Qing - an ( Shenhua Group Corporation Limited, Beijing 100011, China)
Abstract:Learning from the experience of operation practice on Texaco gasifier in China, reviewed and analyzed the phenomena and reasons of Texaco gasifier wall overheating, and proposed the corresponding solutions.
Keywords:Texaco gasifier  gasifier wall overheating  cause  solution