首页 | 本学科首页   官方微博 | 高级检索  
     

气化炉下降管损伤原因分析及应对措施
引用本文:高春雷.气化炉下降管损伤原因分析及应对措施[J].化肥工业,2011,38(6):58-60.
作者姓名:高春雷
作者单位:兖州煤业榆林能化有限公司 719000
摘    要:通过对下降管内温度分布、气化炉内反应机理等方面分析,发现下降管损伤的原因主要是冷却水量不足、炉内产生振动、投料负荷过大或投料液位过高、渣口和下降管挂渣等.根据不同的原因,提出了应对措施,从而延长了气化炉的运行周期.

关 键 词:下降管  损伤  原因分析  应对措施

Analysis of Causes for Damage of Vertical Pipe and Countermeasures
Gao Chunlei.Analysis of Causes for Damage of Vertical Pipe and Countermeasures[J].Journal of the Chemical Fertilizer Industry,2011,38(6):58-60.
Authors:Gao Chunlei
Affiliation:Gao Chunlei (Yulin Energy and Chemicals Co., Ltd. of Yanzhou Coal Ming Co., Ltd. 719000)
Abstract:By an analysis with respect to temperature distribution inside vertical pipe and reaction mechanism inside gasifier, it is found that main causes for the damage of vertical pipe are not enough cooling water, vibration inside gasifier, excessive feeding load, or too much feed, and slag hole and vertical pipe sluggish, etc. Countermeasures are proposed in connection with different causes, thereby extending the operation cycle of the gasifier.
Keywords:vertical pipe damage analysis of causes countermeasure