首页 | 本学科首页   官方微博 | 高级检索  
     


Comparison of microleakage of a multi-mode adhesive system with contemporary adhesives in class II resin restorations
Authors:Duygu Tuncer  Çi?dem Çelik  Sevi Burçak Çehreli  Neslihan Arhun
Affiliation:1. Department of Restorative Dentistry, School of Dentistry, Baskent University, 11.sokak No: 26 Bah?elievler 06490, Ankara, Turkeyduygutuncer@baskent.ed.tr;3. Department of Restorative Dentistry, School of Dentistry, Baskent University, 11.sokak No: 26 Bah?elievler 06490, Ankara, Turkey;4. Department of Pedodontics, School of Dentistry, Baskent University, Ankara, Turkey
Abstract:Aim: The aim was to compare the microleakage of resin composite bonded with different adhesive systems in class-II cavities at enamel or dentine margins. Material and methods: 60 extracted human molar teeth received slot cavity preparations on mesial and distal surfaces (mesial cervical margin was prepared in enamel and distal in dentine). They were randomly divided into five groups (n?=?12) according to the adhesive system: Group-A: Silorane Bond (S), Group-B: Adper Single Bond 2 (SB), Group-C: Clearfil SE Bond (CSE), Group-D: Single Bond Universal (USel) (selective etch-and-rinse), Group-E: Single Bond Universal (USE) (all-in-one). The preparations were restored using the same resin composite (Filtek Ultimate) except Group A which was restored by Silorane composite. The teeth were thermocycled, immersed in dye, sectioned, and dye penetration was evaluated quantitatively using image analysis. The data were analyzed using the two-way analysis of variance and Bonferroni test. Results: In all groups, there was no statistically significant difference between enamel margins at occlusal and gingival sites (p?>?0.05). The statistical difference between Group-A (S) and Group-B (SB) was significant at all margins. Group-B (SB) presented the greatest microleakage amounts at all margins and the highest scores were obtained in the dentine. Likewise, SB demonstrated statistically significant differences between dentine and enamel margins (occlusal and gingival)(p?<?0.05). Conclusion: All adhesive systems showed similar microleakage values between enamel margins in occlusal and gingival regions. However, when the gingival margin is located in the dentine, etch&rinse adhesive systems may not be a choice in terms of microleakage prevention.
Keywords:class II cavity  dental materials  microleakage  multi-mode adhesive  resin composite
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号