首页 | 本学科首页   官方微博 | 高级检索  
     


Effect of heat treatment on the roughness and mechanical properties of dental lithium disilicate glass-ceramics
Affiliation:1. Department of Materials and Ceramics Engineering, University of Aveiro, CICECO, Aveiro, 3810-193, Portugal;2. Rio de Janeiro State University, Faculty of Technology, UERJ-FAT, Rodovia Presidente Dutra, km 298, Resende, RJ27537-000, Brazil;3. Instituto Militar de Engenharia, Materials Science Department, Pça Gen. Tibúrcio, 80, Praia Vermelha, 22290-270, Rio de Janeiro, RJ, Brazil;4. Fluminense Federal University, Faculty of Dentistry, Institute of Health of Nova Friburgo, Dr. Silvio Henrique Braune St, 22, Downtown, Nova Friburgo, RJ, 28625-650, Brazil
Abstract:In dental clinics, it is common to perform small fitting adjustments in dentures using a micro-grinding tool after testing them in the patient's mouth. This procedure increases local roughness and can lead to formation of microcracks on the prosthesis surface. This study aimed to investigate the benefits of a post-finishing heat treatment to surface roughness and crack healing and its effect on the flexural strength of lithium disilicate (LD) dental glass-ceramics. Commercially available lithium metasilicate, Li2SiO3, samples were heat treated at 840 °C for 7 min to induce the phase transformation into LD, Li2Si2O5. The LD samples were characterized by X-ray Diffraction, Scanning Electron Microscopy, Vickers hardness, Young’s modulus, and fracture toughness. One of the surfaces of the LD samples was sanded aiming to simulate the denture fitting adjustments performed in the dentist’s laboratory, generating a rough surface, Group 1. Half of the LD samples had their biaxial flexural strength evaluated by the piston-on-three-ball test (P–3B) and the other half were submitted to a second short-term heat treatment (840 °C - 5 min), Group 2, and later assessed by the P–3B. Roughness parameters in both groups were measured by 3D optical profilometry. After the crystallization heat treatment, formation of elongated LD crystals, Li2Si2O5, 35% amorphous phase, and residual Li3PO4 was observed. In addition, the following mechanical property values were obtained: Vickers hardness = 5.8 ± 0.1 GPa, fracture toughness = 2.2 ± 0.1 MPa m1/2, and Young’s modulus = 100.3 ± 0.3 GPa. The samples in Group 1 showed bending strength of 206 ± 30 MPa and the following roughness parameters: Ra = 0.45 ± 0.16 μm, Rz = 22.7 ± 6.7 μm, and PV = 27.7 ± 7.1 μm. In the samples in Group 2, the Ra, Rz and PV roughness parameters were 0.31 ± 0.12 μm, 5.2 ± 2.5 μm, and 9.2 ± 4.7 μm, respectively. With this decrease in roughness, the bending strength increased by 62%, with a mean value of 331 ± 59 MPa. In the need for machine finishing of LD-based glass-ceramic dental prostheses, the use of a second short-term heat treatment at 840 °C for 5 min generates considerable gains in bending strength, increasing the lifecycle of the prosthesis as a result of reduced surface roughness caused by softening of the remaining amorphous phase in the glass-ceramic. These conditions can be adapted to each chemical and crystallographic composition of the glass-ceramic under study.
Keywords:Dental ceramics  Lithium silicate  Heat treatment  Flexural strength  Surface roughness
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号