首页 | 本学科首页   官方微博 | 高级检索  
     

新型高强度聚焦超声乳化柴油的研究
引用本文:周圆,汤旭东,叶方伟,曾德平,王华.新型高强度聚焦超声乳化柴油的研究[J].化工进展,2013,32(5):1025-1029.
作者姓名:周圆  汤旭东  叶方伟  曾德平  王华
作者单位:1.重庆医科大学生物医学工程学院,省部共建超声医学工程国家重点实验室,超声医学工程重庆市市级重点实验室,重庆 400016;2超声医疗国家工程研究中心,重庆 401121
基金项目:国家重大仪器专项(81127901)
摘    要:采用高强度聚焦超声新技术对柴油乳化进行了研究。实验选择Span80和Tween80两种乳化剂按不同比例进行复配,乳化剂用量(质量分数)为0.9%,含水率为9%。实验结果表明,球形超声聚焦设备不但可以为乳化提供较高能量,而且可以产生强烈的空化和搅拌。高速摄影显示,空化效应和界面不稳定性是这种球形高强度聚焦超声产生乳化的机制。实验结果显示,最佳HLB值为5.4,最佳输入电功率为950 W,乳化300 s就可以得到比较稳定的柴油乳液。乳液粒径可以达到0.5 μm,且分布均匀,稳定时间在6个月以上。通过对比,高强度聚焦超声的乳化效果和乳化效率明显优于变幅杆式超声发生器和磁力搅拌器,为柴油乳化提供了一个具有重要意义的乳化方式。

关 键 词:高强度聚焦超声  柴油  乳化  高效  稳定性    

Study on the emulsification of diesel fuel by a new technology of high intensity focused ultrasound
ZHOU Yuan,TANG Xudong,YE Fangwei,ZENG Deping,WANG Hua.Study on the emulsification of diesel fuel by a new technology of high intensity focused ultrasound[J].Chemical Industry and Engineering Progress,2013,32(5):1025-1029.
Authors:ZHOU Yuan  TANG Xudong  YE Fangwei  ZENG Deping  WANG Hua
Affiliation:1Chongqing Municipal Key Laboratory of Ultrasound Engineering in Medicine,State Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and MOST,College of Biomedical Engineering,Chongqing Medical University,Chongqing 400016,China;2National Engineering Research Center of Ultrasound Medicine,Chongqing 401121,China
Abstract:A new technology of high intensity focused ultrasound was used to study the emulsion of water-in-diesel. The surfactants Span80 and Tween80 were chosen. The mass fraction of surfactant and water were 0.9% and 9% respectively. The result showed that spherical focused ultrasound setup could not only provide high energy,but also induce intensive cavitation and stir. The using of high speed photography technology showed that cavitation and interfacial instability also were the main principle of this kind of emulsification. The optimum HLB was 5.4 and the optimum input power was 950W. Insonation time 300s could produce fine emulsions. With optimum HLB value 5.4,water could be well-distributed in diesel and the droplet size was as low as 0.5μm. The stabilization time of the emulsion could be more than six months. Compared with using insonation equipment with sonotrode and magnetic stirrer methods,the spherical focused ultrasound setup was better both in effect and efficiency. This setup provided a novel and significant method for water-in-diesel emulsification.
Keywords:high intensity focused ultrasound  diesel  emulsification  efficient  stability
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《化工进展》浏览原始摘要信息
点击此处可从《化工进展》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏