首页 | 本学科首页   官方微博 | 高级检索  
     

济钢制氧机直流冷却水的技改经验
引用本文:张文元.济钢制氧机直流冷却水的技改经验[J].工业水处理,2000,20(1):46-46.
作者姓名:张文元
作者单位:济钢集团总公司氧气厂!山东济南,250101
摘    要:介绍了制氧机直流供冷却水改造成缓蚀阻垢加药处理循环供水的情况及其生产中的应用效果。改造后,系统各种技术参数均达到设计要求,循环水能满足制氧设备冷却要求,降低了氧气生产成本,提高了设备使用寿命,节约大量地下水资源,两个半月可收回投资,效益显著,运行可靠。

关 键 词:直流供水  循环水  加药处理  冷却水  水处理
修稿时间::

Experience of the technical innovation of the direct cooling water in the oxygen extractors in Jinan Iron and Steel Group Co.
ZHANG Wen,yuan.Experience of the technical innovation of the direct cooling water in the oxygen extractors in Jinan Iron and Steel Group Co.[J].Industrial Water Treatment,2000,20(1):46-46.
Authors:ZHANG Wen  yuan
Abstract:This article introduces the situation after changing the direct cooling water supply in oxygen extractors into circulating water supply by feeding corrosion inhibitor and scale inhibitor simultaneously. Its application in production is also introduced.
Keywords:direct cooling water supply  circulating water supply  agent-feeding treatment