MDEA换热器泄漏快速检测方法研究
引用本文:黄坤.MDEA换热器泄漏快速检测方法研究[J].硫酸工业,2021(2):52-56.
作者姓名:黄坤
作者单位:中国石化中原油田普光分公司天然气净化厂
摘    要:介绍了气相色谱法检测循环水中N-甲基二乙醇胺(MDEA)的方法,用于定位泄漏的MDEA换热器。确定了气相色谱法检测水中MDEA的检测条件,单个样品检测时间约6 min,相对标准偏差(RSD)值小于2.5%,加标回收率92%~120%,方法准确可靠。与传统的COD法相比,气相色谱法节省了定位泄漏换热器的时间,降低了泄漏的MDEA对循环水的污染程度,具有较好的参考借鉴价值。

关 键 词:气相色谱  N-甲基二乙醇胺  换热器  泄漏  检测

Research on rapid detection method of MDEA heat exchanger leakage
HUANG Kun.Research on rapid detection method of MDEA heat exchanger leakage[J].Sulphuric Acid Industry,2021(2):52-56.
Authors:HUANG Kun
Affiliation:(Natural Gas Purification Plant,Puguang Branch of SINOPEC Zhongyuan Oil Field,Dazhou,Sichuan,635000,China)
Abstract:The gas chromatography method for the detection of N-methyldiethanolamine(MDEA)in circulating water is introduced,which is used to locate the leakage of MDEA heat exchanger.The detection conditions of MDEA in water by gas chromatography are determined.The detection time of a single sample is about 6 min,the relative standard deviation(RSD)value is less than 2.5%,and the recovery rate is 92%-120%.The method is accurate and reliable.Compared with the traditional COD method,it saves the time of locating the leakage heat exchanger,reduces the pollution degree of the leakage MDEA to the circulating water,and has a good reference value.
Keywords:gas chromatography  N-methyldiethanolamine  heat exchanger  leak  testing