固定管板式换热器管板的有限元分析
引用本文:陈慕天,谢禹钧,张芳瑶.固定管板式换热器管板的有限元分析[J].当代化工,2014(7):1227-1229.
作者姓名:陈慕天  谢禹钧  张芳瑶
作者单位:辽宁石油化工大学机械工程学院,辽宁抚顺113001
摘    要:应用ANSYS软件对固定管板式换热器管板进行应力分析,得到管程压力,壳程压力和热载荷三个不同工况组合下管板的应力,并根据JB4732-95《钢制压力容器-分析设计标准》对危险截面进行应力强度评定。分析结果表明,管板的强度满足要求,此文的研究方法为同类型换热器安全评估提供了参考。

关 键 词:换热器  ANSYS  管板  强度评定

Finite Element Analysis of the Tube Sheet in a Fixed Tube Sheet Heat Exchanger
CHEN Mu-Tian,XIE Yu-jun,ZHANG fang-yao.Finite Element Analysis of the Tube Sheet in a Fixed Tube Sheet Heat Exchanger[J].Contemporary Chemical Industry,2014(7):1227-1229.
Authors:CHEN Mu-Tian  XIE Yu-jun  ZHANG fang-yao
Affiliation:(Liaoning Shihua University, Liaoning Fushun 113001, China)
Abstract:The stress of tube-sheet heat exchanger was analyzed by using the ANASYS software, the stresses of tube-sheet under three different load conditions of tube side pressure, shell pressure and thermal load were obtained, respectively. According to the JB4732-95 Steel pressure vessels-the standard of analysis design, the strength of the dangerous sections was assessed. The analysis results indicated that the intensity requirement of the tube-sheet was satisfied. The paper can provide the reference for the safety assessment of the heat exchanger in service.
Keywords:ANSYS  Heat exchanger  ANSYS  Tube-sheet  Strength assessment