UV/Fenton处理苯酚废水的研究 |
| |
引用本文: | 王来斐.UV/Fenton处理苯酚废水的研究[J].化工给排水设计,2012(5):20-22,31. |
| |
作者姓名: | 王来斐 |
| |
作者单位: | 上海勘测设计研究院,上海200434 |
| |
摘 要: | 采用UV/Fenton联合体系降解苯酚模拟废水,苯酚的初始质量浓度为300mg/L,COD。的初始质量浓度为760mg/L。探讨了pH值、H202(30%)和FeSO4·7H2O投加量、反应时间等因素对苯酚和CODcr去除率的影响。结果表明,UV/Fenton联合体系降解苯酚废水的最佳工艺条件是:溶液pH值为3、H2O2投加量为2.5mL/L、FeS04·7H20投加量为0.020g/L、反应时间为90min。此时,苯酚的去除率为95%,CODcr的去除率为90%。UV/Fenton联合体系能较好地处理苯酚废水。
|
关 键 词: | Fenton试剂 苯酚 紫外光 废水处理 |
Treatment of phenol-containing wastewater by UV-Fenton process |
| |
Authors: | WANG Lai-fei |
| |
Affiliation: | WANG Lai-fei (Shanghai Investigation, Design and Research Institute, Shanghai 200434, China) |
| |
Abstract: | UV-Fenton process was used to treat simulant phenol-containing wastewater, the initial mass concentrations of phenol and CODc4 were 300 and 760 mg/L respectively. The effects of pH value, dosage of H202(30%) and FeSO4 7H20, reaction time and some other factors on the removal rates of phenol and CODcr were discussed. The results showed that, the optimal condition for UV-Fenton process treating phenol-containing wastewater was as follows: the solution pH value was 3, the dosage of H202 and FeSO4-7H20 were 2.5 mL/L and 0.020 g/L respectively, the reaction time was 90 min. Under the above condition, the removal rates of phenol and CODcr reached 95% and 90% respectively. It could be seen that, UV-Fenton process was effective for the treatment of phenol-containing wastewater. |
| |
Keywords: | Fenton reagent phenol UV wastewater treatment |
本文献已被 维普 等数据库收录! |
|