首页 | 本学科首页   官方微博 | 高级检索  
     

芬顿法处理肝素废水影响因素的探讨
引用本文:解恒参.芬顿法处理肝素废水影响因素的探讨[J].徐州建筑职业技术学院学报,2010,10(1):30-33.
作者姓名:解恒参
作者单位:徐州建筑职业技术学院,科技与产业处,江苏,徐州,221116
摘    要:通过正交实验设计对Fenton试剂处理肝素废水的影响因素进行讨论,得出了影响因素的次序及最佳工艺条件.即:pH值〉Fe^2+的投加量〉H2O2的投加量〉反应时间;在pH为6.00,FeSO4·7H2O的投加量为2.5g/L,H2O2的投加量为2.75(‰,V/V)的条件下,搅拌25min,CODQ值由预处理后的1268.44mg/L降至不足70mg/L,CODcr去除率达到94.5%.

关 键 词:肝素废水  Fenton试剂  正交实验设计

Influencing Factors on Treatment of Heparin Sodium Wastewater with Fenton's Reagent
XIE Heng-shen.Influencing Factors on Treatment of Heparin Sodium Wastewater with Fenton''s Reagent[J].Journal of XUZHOU Institute of Architectural Technology,2010,10(1):30-33.
Authors:XIE Heng-shen
Affiliation:XIE Heng-shen(Division of Science & Technology,Xuzhou Institute ofArchitectural Technology,Xuzhou,Jiangsu 221116,China)
Abstract:By orthogonal experiment design method, this paper discussed the influencing factors on the treatment of heparin sodium wastewater with Fenton's reagent, which resulted in the sequence of influencing factors and the best technological conditions. The results showed that the sequence of influencing factors was pH value, amount of Fe^2+ , dosage of H2O2 and reaction time, and with pH value of 6.00, FeSO4 - 7H20 dosage of 2.5 g/L,H2 O2 concentration of 2.75‰(V/V) and churning time of 25 rain, CODcr reduced from 1 268.44 mg/Lafter pre-treating to less than 70mg/L, the removal efficiency of which reached 94.5 %.
Keywords:heparin sodium wastewater  Fenton\'s reagent  orthogonal experiment design  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏