首页 | 本学科首页   官方微博 | 高级检索  
     

GIS组合电器的安装要点分析
引用本文:段峰彪.GIS组合电器的安装要点分析[J].沈阳工程学院学报(自然科学版),2012,8(3):232-234.
作者姓名:段峰彪
作者单位:山东核电有限公司工程部,山东海阳,265116
摘    要:GIS组合电器因具有占地小、噪音小、火灾危险性小、检修周期长、运行安全可靠等特点,特别适用于智能型变电站,同时此种设备对安装质量有较高的要求.结合自身在220 kV和500 kV GIS工作经验,将GIS组合电器的特点、安装程序和工艺要求及关键的质量控制要点加以总结,为今后GIS组合电器安装提供参考.

关 键 词:GIS组合电器  安装程序  工艺要求  质量控制

Analysis on key points of installation of GIS combined electrical equipment
DUAN Feng-biao.Analysis on key points of installation of GIS combined electrical equipment[J].Journal of Shenyang Institute of Engineering:natural Science,2012,8(3):232-234.
Authors:DUAN Feng-biao
Affiliation:DUAN Feng-biao(Engineering Department,Shandong Nuclear Power Company Ltd.,Yantai 265116,China)
Abstract:GIS combined electrical equipment are especially suitable for intelligent substation for its characteristic of smaller foot print,low noise,low fire risk,long maintenance period,safe and reliable operation.At the same time,such equipments require high installation quality.Combining the work experience on GIS in 220kV and 500kV substations,the GIS characteristic,installation procedure,process requirements and key quality control points are summarized,it provides reference for the installation of GIS composite electric installation.
Keywords:GIS composite electric installation  installation procedure  process requirements  quality control
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号