摘    要:为了研究单边连接高强角钢在输电铁塔中的受力性能,以48根Q460高强角钢为研究对象,对高强角钢双向压弯受力性能进行了静力加载试验研究.研究了压杆不同长细比时高强角钢的破坏模式、承载力、变形性能、截面应变分布等受力状态.试验表明,构件绕连接肢发生弯曲变形,同时伴有绕角钢纵轴的扭转变形,小长细比试件大多为局部屈曲,大长细比试件为整体屈曲.有限元数值模拟了实际试件的受力性能,结果表明:有限元分析的极限承载力结果偏大,美国ASCE规范值偏于保守,试验值处于美国规范值和有限元分析值之间,且靠近于有限元值.在模型试验和仿真试验的基础上,提出了单边连接高强角钢等效长细比公式.因此,试验结果可以为Q460高强角钢设计提供依据.

关 键 词:高强角钢  试验研究  仿真分析  等效长细比

Experimentation study and simulation analysis on high strength single-angle compression members attached by one leg
HAO Ji-ping,CAO Xian-lei,ZHANG Tian-guang,GUO Yong-hua,WANG Xian-tie,FAN Chun-lei.Experimentation study and simulation analysis on high strength single-angle compression members attached by one leg[J].Journal of Xi'an University of Architecture & Technology,2009,41(6).
Authors:HAO Ji-ping  CAO Xian-lei  ZHANG Tian-guang  GUO Yong-hua  WANG Xian-tie  FAN Chun-lei
Abstract:In order to study the bearing capacity of Q460 high-strength single-angle attached by one leg in transmission tower, using 48 high-strength angle steel as specimens, the behavior about press-bending bearing capacity of high-strength single-angle were put to test under static loading. Experimental studies were carried out to investigate failure process, bearing capacity, deformation performance and strain distribution of high-strength angle steel. The experiment result shows: members bend round connection leg,with twisting deformation taking place at the same time. Most of the small slenderness members were controlled by local buckling , and the large members were controlled by overall buckling .The bearing capacity of members were analyzed by finite element numerical simulation analysis , and compared with the experimental results and American ASCE10-1997 results.The results shows that the finite element analysis of the ultimate strength results are largest, results of ASCE are conservative, experiment data are between the code of ASCE and the finite element analysis, but experiment results are close to the finite element analysis. Based on model experiment and simulated experiment, the formula of equivalent slenderness ratio was established .Therefore, the results can provide design reference for Q460 high-strength single-angle.
Keywords:high strength angle steel  experimentation study  simulation analysis  equivalent slenderness ratio