拉力试验机常见电气故障的排除
引用本文:郭维.拉力试验机常见电气故障的排除[J].电气开关,2005,43(4):45-45,48.
作者姓名:郭维
作者单位:沈阳市产品质量监督检验所,辽宁,沈阳,110021
摘    要:通过对0~25N拉力试验机常见电气故障剖析和分步提出排除故障的具体方法,使同行对拉力试验机常见电气故障的排除有一个清晰的认识.采用本文中的逻辑推理排除法,可在较短时间内将故障排除,节省时间,少走弯路,用更多精力做好其它分析试验工作.

关 键 词:排除法  触点粘连  弧光电流  反馈绕组
文章编号:1004-289X(2005)04-0045-02
收稿时间:2005-06-06
修稿时间:2005-06-06

Common Electrical Trouble Removal of A Tensile Testing Machine
GUO Wei.Common Electrical Trouble Removal of A Tensile Testing Machine[J].Electric Switchgear,2005,43(4):45-45,48.
Authors:GUO Wei
Abstract:By analysis and steps to common electrical trouble of 0~25 tensile testing machine,specific method of trouble clearing is propesed. It makes the peron of the same trade has a correct knowledge about the common electrical trouble removal. Logical inference is adopted in the paper. It can eliminate faults in short time and save time in order to do the other analysis and tesk work well in more vitality.
Keywords:exclusive method  contact adhseion  arc current  feedback winding