摘    要:阐述了华东500 kV电网网损现状及存在的问题,经分析给出了影响华东500kV电网网损的,包括电力需求、电网建设电网改造及电网运行等因素,并在此基础上提出了优化电网运行方式、做好电网经济调度、强化电网无功平衡工作、加强网损理论分析等建议。

关 键 词:华东电网  网损率  电网建设  电力需求

Network loss analysis for 500 kV grids of East China
CAO Mei-zhen.Network loss analysis for 500 kV grids of East China[J].East China Electric Power,2008(4).
Authors:CAO Mei-zhen
Abstract:The status quo and existing problems of network loss of the 500 kV grid in East China are presented,and factors influencing network loss of the grid are analyzed,including the factors of power demand,the grid construction and retrofit,and grid operational modes.Based on that,relevant suggestions are proposed,such as optimizing the grid operational mode,implementing economic dispatching,enhancing reactive power balance,and strengthening theoretical analysis of network loss.
Keywords:East China Power Grid  grid loss rate  grid construction  power demand