一种应用于智能变电站和调度主站之间的通信映射方法
引用本文:朱桂英,张鸿,黄海峰,胡继昊,张海东,许先锋.一种应用于智能变电站和调度主站之间的通信映射方法[J].继电器,2014,42(14):112-116.
作者姓名:朱桂英  张鸿  黄海峰  胡继昊  张海东  许先锋
作者单位:中国电力科学研究院南京分院,江苏 南京 210003;中国电力科学研究院南京分院,江苏 南京 210003;中国电力科学研究院南京分院,江苏 南京 210003;中国电力科学研究院南京分院,江苏 南京 210003;中国电力科学研究院南京分院,江苏 南京 210003;中国电力科学研究院南京分院,江苏 南京 210003
摘    要:随着智能电网建设的深入推进,主站和变电站间模型及信息共享要求剧增,而目前子站与主站间的常用通信规约已无法满足通信的需求。提出了一种实时服务通信协议,它以IEC61850为基础,在特定通信服务映射开放性的基础上,直接将抽象通信服务接口(ACSI)映射到TCP/IP通信协议栈,构建适应于智能电网建设需要的通信规约,满足智能变电站与主站间无缝通信要求。同时还提出了相关模型的转换方法及校验方法。

关 键 词:IEC  IEC  智能变电站  调度主站  无缝通信
收稿时间:2013/10/10 0:00:00
修稿时间:2013/12/24 0:00:00

A mapping method of communication applied to smart substation and control center
ZHU Gui-ying,ZHANG Hong,HUANG Hai-feng,HU Ji-hao,ZHANG Hai-dong and XU Xian-feng.A mapping method of communication applied to smart substation and control center[J].Relay,2014,42(14):112-116.
Authors:ZHU Gui-ying  ZHANG Hong  HUANG Hai-feng  HU Ji-hao  ZHANG Hai-dong and XU Xian-feng
Affiliation:China Electric Power Research Institute, Nanjing 210003, China;China Electric Power Research Institute, Nanjing 210003, China;China Electric Power Research Institute, Nanjing 210003, China;China Electric Power Research Institute, Nanjing 210003, China;China Electric Power Research Institute, Nanjing 210003, China;China Electric Power Research Institute, Nanjing 210003, China
Abstract:With the smart grid construction boosting further, the requirements of model and information sharing between control center and substation increase, while the current commonly used communication protocol between control center and substation has been unable to meet the demand of communication. This paper proposes a real-time service communication protocol based on IEC61850. On the basis of specific communication service mapping openness, the abstract communication service interface (ACSI) is directly mapped to the TCP/IP communication protocol stack to build up a communication protocol in smart grid construction needs and meet the intelligent seamless communication requirements between control center and substation. The model conversion method and calibration method are also proposed.
Keywords:IEC61850  IEC61970  smart substation  control center  seamless communication