首页 | 本学科首页   官方微博 | 高级检索  
     


Optimal power flow by BAT search algorithm for generation reallocation with unified power flow controller
Affiliation:1. Department of Electrical Engineering, Marvdasht Branch, Islamic Azad University, Marvdasht, Iran;2. School of Electrical Engineering and Telecommunications, The University of New South Wales, Sydney, Australia;1. Department of Electrical & Computer Engineering, University of Sharjah, P.O. Box 27272, Sharjah, United Arab Emirates;2. Research Consultant, 16 First Avenue, Eastwood, NSW 2122, Australia;1. School of Electrical Engineering and Telecommunications, The University of New South Wales, Sydney, Australia;2. Department of Electrical Engineering, Marvdasht Branch, Islamic Azad University, Marvdasht, Iran;1. Hormozgan Electricity Distribution Company, Bandar Abbas, Iran;2. Department of Electrical Engineering, Science and Research Branch, Islamic Azad University, Fars, Iran;3. Department of Electrical Engineering, Najafabad Branch, Islamic Azad University, Najafabad, Iran;1. Department of Electrical Engineering, Islamic Azad University, Lamerd Branch, Lamerd, Iran;2. The Australian Energy Research Institute and the School of Electrical Engineering and Telecommunications, University of New South Wales (UNSW Australia), Sydney 2052, NSW, Australia;3. Life Senior Member IEEE, Sharaf Energy Systems, Inc., Fredericton, NB, Canada;4. Department of Electrical Engineering, Marvdasht Branch, Islamic Azad University, Marvdasht, Iran
Abstract:Optimal power flow with generation reallocation is a suitable method for better utilization of the existing system. In recent years, Flexible AC Transmission System (FACTS) devices, have led to the development of controllers that provide controllability and flexibility for power transmission. Out of the FACTS devices unified power flow controller (UPFC) is a versatile device, capable of controlling the power system parameters like voltage magnitude, phase angle and line impedance individually or simultaneously. The main aim of this paper is to minimize real power losses in a power system using BAT search algorithm without and with the presence of UPFC. Minimization of real power losses is done by considering the power generated by generator buses, voltage magnitudes at generator buses and reactive power injection from reactive power compensators. The proposed BAT algorithm based Optimal Power Flow (OPF) has been tested on a 5 bus test system and modified IEEE 30 bus system without and with UPFC. The results of the system with and without UPFC are compared in terms of active power losses in the transmission line using BAT algorithm. The obtained results are also compared with Genetic algorithm (GA).
Keywords:BAT algorithm  FACTS device  Optimal power flow  UPFC
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号