含恒功率负载的弱电网线路阻抗稳定区间辨识:阻抗技术
引用本文:王睿,孙秋野,秦德豪,胡伟,马大中,李相科.含恒功率负载的弱电网线路阻抗稳定区间辨识:阻抗技术[J].中国电机工程学报,2021(4):1284-1294.
作者姓名:王睿  孙秋野  秦德豪  胡伟  马大中  李相科
作者单位:东北大学信息科学与工程学院;克莱姆森大学工程、计算与应用科学学院;湖南大学机械与运载工程学院;南洋理工大学能源研究所
基金项目:国家重点研发计划项目(2018YFA0702200);国家自然科学基金项目(U20A20190,62073065)。
摘    要:弱电网因其易发生低频振荡和谐波振荡现象而被广泛研究。然而,传统的阻抗方法更注重于线路阻抗稳定运行点的辨识和回比矩阵的稳定裕度,而不能提供具体的线路阻抗稳定区间。因此,文中提出一种基于安全保护映射理论的弱电网线路阻抗稳定区间辨识方法,以求为实际系统规划和相关回稳方法研究提供指导。首先,分别建立交流弱电网的源侧阻抗矩阵和载侧导纳矩阵。然后,对上述互联系统建立稳定禁止区间,并进一步转化为稳定运行区间。其与基于范数的阻抗准则相比,该稳定区间的保守性显著降低。进而,通过镜像、平移和旋转映射互联系统的回比矩阵将线路阻抗稳定区间的求解过程转化为Hurwitz矩阵的辨识问题,并且通过安全保护映射理论直接得到线路阻抗稳定运行区间。最后,通过仿真和实验结果验证该方法的保守性和有效性。

关 键 词:弱电网  稳定裕度  禁止区域  阻抗技术

Stability-oriented Line Impedance Domain Assessment for Weak Grids With Constant Power Loads:An Impedance-based Approach
WANG Rui,SUN Qiuye,QIN Dehao,HU Wei,MA Dazhong,LI Xiangke.Stability-oriented Line Impedance Domain Assessment for Weak Grids With Constant Power Loads:An Impedance-based Approach[J].Proceedings of the CSEE,2021(4):1284-1294.
Authors:WANG Rui  SUN Qiuye  QIN Dehao  HU Wei  MA Dazhong  LI Xiangke
Affiliation:(School of Information Science and Engineering,Northeastern University,Shenyang 110819,Liaoning Province,China;College of Engineering,Computing and Applied Sciences,Clemson University,29405,South Carolina,USA;College of Mechanical and Vehicle Engineering,Hunan University,Changsha 410082,Hunan Province,China;Energy Research Institute,Nanyang Technological University,637141,Singapore)
Abstract:Weak grids are gaining considerable attention since power generation resources are remote from power loads,which results in low-frequency/harmonic oscillation.However,the conventional impedance-based approach pays more attention to the identification of line impedance stable operating points and the stability margin of the return-ratio matrix,but it cannot provide detailed system parameter stability region.Thus,this paper proposed a line impedance stability region analysis method for the weak grid to provide the guidance for practical system planning and related stabilization method researches.Firstly,the source impedance and load admittance matrices for the AC weak grid were separately built.Then,the forbidden region was constructed for the above interconnected system,and it was further transformed into the stability operation region.Compared with the norm-based impedance criteria,the conservatism of the proposed stability region is significantly reduced.Moreover,the solution process of the line impedance stability region was switched as the identification problem regarding Hurwitz matrix through mirror,translation and rotation mapping of the interconnected system return-ratio matrix,and the line impedance stability region was directly obtained by guardian map theory.Eventually,the simulation and experimental results verified the conservatism and effectiveness of the proposed method.
Keywords:weak grid  stability domain  stability forbidden region  impedance-based approach