用归一化等效瞬时电感分布特性识别励磁涌流的新算法
引用本文:郑涛,刘万顺,庄恒建,李肖博.用归一化等效瞬时电感分布特性识别励磁涌流的新算法[J].中国电机工程学报,2005,25(23):47-53.
作者姓名:郑涛  刘万顺  庄恒建  李肖博
作者单位:1. 电力系统保护与动态安全监控教育部重点实验室(华北电力大学),北京市,昌平区,102206
2. 国电龙源环保工程有限公司,北京市,宣武区,100761
基金项目:国家自然科学基金项目(50277012).
摘    要:针对具有Y/△接线方式的三相变压器,提出了一种新的变压器差动保护TA配置方案:该方案是在传统变压器差动保护接线基础上,在变压器△侧接入一相绕组TA,然后与所测得的线电流结合,利用KCL定律可以容易地求解出△侧各相绕组电流.该方案既保证了等效瞬时电感的准确计算,使其不受△侧绕组内部环流的影响,又不会使差动保护存在"死区".在此基础上,文中提出一种基于归一化等效瞬时电感分布特性的励磁涌流识别新算法:对等效瞬时电感进行归一化处理,使判据定值的选取更具有普遍性,与具体变压器参数、类型无关;利用分布特性更好地反映了等效瞬时电感的变化特征和规律.新算法识别灵敏可靠,HYBRISIM(Hybrid Simulator)实验数据也验证了新算法的准确性和有效性,其在超高压大容量变压器保护方面具有较好的工程应用前景.

关 键 词:电力系统  等效瞬时电感  励磁涌流  变压器差动保护  分布特性
文章编号:0258-8013(2005)23-0047-07
收稿时间:2005-09-28
修稿时间:2005年9月28日

A NEW ALGORITHM BASED ON THE DISTRIBUTION OF THE NORMALIZED EQUIVALENT INSTANTANEOUS INDUCTANCE FOR THE DISCRIMINATION OF INRUSH
ZHENG Tao,LIU Wan-shun,Zhuang Heng-jian,LI Xiao-bo.A NEW ALGORITHM BASED ON THE DISTRIBUTION OF THE NORMALIZED EQUIVALENT INSTANTANEOUS INDUCTANCE FOR THE DISCRIMINATION OF INRUSH[J].Proceedings of the CSEE,2005,25(23):47-53.
Authors:ZHENG Tao  LIU Wan-shun  Zhuang Heng-jian  LI Xiao-bo
Affiliation:ZHENG Tao, LIU Wan-shun, Zhuang Heng-jian, LI Xiao-bo , Ministry of Education, Changping District, Beijing 102206, China; 2. SP Longyuan Environment Engineer, Xuanwu District, Beijing 100761, China)
Abstract:Oriented to wye-delta connected three phase transformer,a new configuration of current transformer(CT)in transformer differential protection is proposed.In this configuration,only one single phase CT connected in any phase of the delta side is more needed than the traditional scheme.Worked with line currents measured by other current transformers connected in both sides of the transformer,any phase current in the delta side can be calculated based on the Kirchhoff's Current Law.This new scheme ensures the accurate calculation of the equivalent instantaneous inductance,which is immune to the loop current existed in the delta side of transformer,as well as no dead zone in transformer differential protection.A new algorithm based on the distribution of the normalized equivalent instantaneous inductance for the discrimination between inrush current and fault current is proposed.The normalization of equivalent instantaneous inductance makes the setting-value have little relation with the parameter of transformers,which has more universal meaning in the determination of setting values.Utilizing the distributive characteristic of the normalized equivalent instantaneous inductance,the variety of the normalized equivalent instantaneous inductance is effectively revealed.At last,experiment data obtained from HYBRISIM(Hybrid Simulator)validates the reliability and sensitivity of this algorithm.This algorithm has good prospect of engineering application in the EHV transformer protection.
Keywords:Power system  Equivalent instantaneous inductance  Inrush currents  Transformer differential protection  Distribution