摘    要:阀控铅酸(VRLA)电池的合理维护是保障通讯的根本措施.应对温度进行监控、正确设置浮充电压、进行充放电测试和控制放电深度.采取端电压测量、核对性放电、在线快速容量测试和电导(内阻)测量等方法,监测电池的状态.

关 键 词:阀控铅酸(VRLA)电池  容量  维护

The maintenance of valve regulated lead-acid battery for communication
ZHOU Shu-hui,QIN Shu-ming,HE Xiao.The maintenance of valve regulated lead-acid battery for communication[J].Battery Bimonthly,2009,39(2).
Authors:ZHOU Shu-hui  QIN Shu-ming  HE Xiao
Affiliation:Hunan Branch;China TieTong Telecommunications Corporation;Changsha;Hunan 410016;China
Abstract:Proper maintenance of valve regulated lead-acid(VRLA) battery was the fundamental measure to guarantee the communication.It should monitor temperature,set float charge voltage correctly,take charge-discharge test and control discharge depth,monitor the state of battery by methods such as terminal voltage measuring,checking discharge,online express capacity test and conductivity(resistance) measuring.