摘    要:针对崇左电网A类电压合格率低于年度指标的问题,通过分析2013年1月-6月崇左电网14个A类电压监测点的电压合格率数据,发现A类电压合格率低与AVC系统策略、远动装置、电容器组容量匹配和电网结构等因素有关.结合电网实际,提出了优化AVC系统策略、升级远动装置版本、增加无功就地补偿容量等提高A类电压合格率的改进措施.改进措施实施后,崇左电网A类电压合格率得到有效提高.

关 键 词:自动电压控制(AVC)系统  A类电压  电压合格率  无功电压

Analysis and Measures to Improve the Qualification Rate of Class A Voltage in Chongzuo Power Grid
BIAN Qinghua.Analysis and Measures to Improve the Qualification Rate of Class A Voltage in Chongzuo Power Grid[J].Guangxi Electric Power,2014,37(6):77-79.
Authors:BIAN Qinghua
Affiliation:BIAN Qinghua (Chongzuo Power Supply Bureau, Guangxi Power Grid Co., Ltd., Chongzuo 532200, China)
Abstract:Aiming at the problem that the qualificaiton rate of class A voltage in Chongzuo power grid is lower than the annual index, data of voltage qualificaiton rate from 14 class A voltage monitoring points from january to june 2013 are analyzed. It is found that the lower qualificaiton rate of class A voltage has realations with factors such as AVC system stratagy, remote device, capacitance matching of capacitor bank and structure of power grid and so on. Based on the acutal situation of power grid, modification measures to improve the qualificaiton rate of class A voltage are proposed such as the optimization of AVC system strategy, the upgrade of remmote device version, the addtion of local reactive compensation capacitance and so on. The qualificaiton rate of class A voltage of Chongzuo power grid is improvec effectively after the implement of the modification.
Keywords:Automatic voltage control (AVC) system  class A voltage  voltage qualification rate  reactive voltage
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号