干式空心电抗器平均温升的拟合计算法
引用本文:赵海翔.干式空心电抗器平均温升的拟合计算法[J].变压器,1999,36(12):7-9.
作者姓名:赵海翔
作者单位:北京电力设备总厂!北京102401
摘    要:介绍了用曲线拟合的方法对干式空心电抗器温升试验后的热态电阻数据进行处理,并利用基于热平衡原理导出的公式计算绕组平均温升的计算方法。这种方法可以有效消除人为因素造成的误差。

关 键 词:干式空心电抗器  平均温升  曲线拟合  电抗器

Fitting Algorithm of Mean Temperature Rise of Dry-Type Air-Core Reactor
Zhao Haixiang Beijing Power Equipment Group,Beijing.Fitting Algorithm of Mean Temperature Rise of Dry-Type Air-Core Reactor[J].Transformer,1999,36(12):7-9.
Authors:Zhao Haixiang Beijing Power Equipment Group  Beijing
Affiliation:Zhao Haixiang Beijing Power Equipment Group,Beijing 102401
Abstract:The thermal resistance data which is got after temperature rise test on dry-type air-core reactor is treated by using curve fitting method. The method of calculating the mean temperature rise of winding is derived from the principle of thermal equilibrium. This method can reduce the errors of human factors.
Keywords:Dry-type air-core reactor  Mean temperature rise  Curve fitting  Calculation