首页 | 本学科首页   官方微博 | 高级检索  
     

APF直流侧电压控制小信号建模及参数整定
引用本文:朱茂琨,盘宏斌,阳建.APF直流侧电压控制小信号建模及参数整定[J].电源学报,2018,16(5):53-58,66.
作者姓名:朱茂琨  盘宏斌  阳建
作者单位:湘潭大学信息工程学院
基金项目:国家自然科学基金资助项目(51577162);湖南省自然科学基金资助项目(14JJ5007)
摘    要:直流侧电压控制是并联型有源滤波器APF(active power filter)的关键环节,精确设计控制器参数有助于提高系统性能。在传统直流侧电压控制模型基础上建立了其控制小信号模型,进而提出一种基于小信号模型的PI参数整定方法。采用零极点配置将含有右半平面零点的小信号模型转化为普通的二阶滞后系统,根据劳斯判据和两步整定法详细讨论了PI参数的选取原则,重点分析不同PI参数对系统性能的影响。该方法在实验参数已知的情况下,可以准确计算出PI控制器参数,在保证系统谐波补偿性能的同时具有较小的直流侧电压超调。仿真和样机实验结果都表明了该方法的可行性。

关 键 词:有源滤波器  直流侧电压  小信号模型  PI参数整定
收稿时间:2016/7/20 0:00:00
修稿时间:2017/12/26 0:00:00

DC-side Voltage Controlled Small-signal Modeling and Parameter Tuning for APF
ZHU Maokun,PAN Hongbin and YANG Jian.DC-side Voltage Controlled Small-signal Modeling and Parameter Tuning for APF[J].Journal of power supply,2018,16(5):53-58,66.
Authors:ZHU Maokun  PAN Hongbin and YANG Jian
Affiliation:College of Information Engineering, Xiangtan University, Xiangtan 411105, China,College of Information Engineering, Xiangtan University, Xiangtan 411105, China and College of Information Engineering, Xiangtan University, Xiangtan 411105, China
Abstract:DC-side voltage control is the key link of shunt active power filter(APF), and a precise design of contro-ller parameters is helpful to the improvement of system performance. Based on the traditional DC-side voltage control model, a small-signal model is established, and a PI parameter tuning method is proposed accordingly. With zero-pole configuration, the small-signal model including right-half plane zero is changed into an ordinary two-order delay system. The selection principle of PI parameters is discussed in detail according to the Routh-criterion and two-step tuning method, and the impact of different PI parameters on the system performance is analyzed specifically. This method can precisely calculate the PI controller parameters when platform parameters are given, and the DC-side voltage can maintain a smaller overshoot while ensuring the system''s harmonic compensation performance. Simulation and experimental results of a prototype verified the feasibility of this method.
Keywords:active power filter  DC-side voltage  small-signal model  PI parameter turning
本文献已被 CNKI 等数据库收录!
点击此处可从《电源学报》浏览原始摘要信息
点击此处可从《电源学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏