A study on improving shielding performance of shielded cable
Authors:Takashi Tsuchida
Affiliation:KANDENKO Co., Ltd, Tokyo, Japan
Abstract:With the developments in power electronics equipment, the electromagnetic environment has become severe for electronic equipment. In the smart facility field, the stable operation of electronic devices is indispensable, and noise countermeasures must be improved. To suppress intrusive noise from cables, shielded cables are used in many cases. However, electromagnetic induction cannot be suppressed when the shield is grounded at one end, and when grounding both ends of the shield, current flows through the shield creating intrusive noise in the cable. That is, even if a shielded cable is used, a sufficient effect cannot be obtained. Therefore, as a countermeasure, this study prototypes and evaluates cables that combine double shielded cables with magnetic cores. Evaluations conducted using the copper pipe method, triaxial method, and impulse test confirm that the shielded performance improved by 10–30 dB compared with the conventional shielded cable.
Keywords:copper-pipe method  EMC  impulse test  shielded cable  shielding effect  triaxial method