电流互感器二次阻抗的现场测试计算
引用本文:何培东,陈英.电流互感器二次阻抗的现场测试计算[J].四川电力技术,2006,29(1):15-17.
作者姓名:何培东  陈英
作者单位:内江电业局,四川内江,641000
摘    要:介绍了电流互感器实际二次阻抗的现场测试、计算方法。该方法所需设备少、重量轻,操作简便;不需新增专用设备,不需三相电源;通用性强,适用于各种形式接线的电流互感器。

关 键 词:电流互感器  实际二次阻抗  测试  计算
文章编号:1003-6954(2006)01-0015-03
收稿时间:2005-10-10
修稿时间:2005年10月10

On-site Test and Calculation of Secondary Impedance of Current Transformer
He Peidong,Chen Ying.On-site Test and Calculation of Secondary Impedance of Current Transformer[J].Sichuan Electric Power Technology,2006,29(1):15-17.
Authors:He Peidong  Chen Ying
Affiliation:He Peidong Chen Ying
Abstract:The method of on - site test and calculation for actual secondary impedance of current transformer have been introduced. The method needs small and light equipment and is easy to opomte. There needs no new special equipment and three- phase power supply. It has strong universality and is suitable for current transformer with various wire connection.
Keywords:current transformer  actual secondary impedance  test  calculation