摘    要:分析了串联补偿电容器用保护间隙和旁路开关的主要用途及其特殊运行条件,根据其主要技术标准要求,提出多种触发间隙和快速开关的技术方案,对这些技术方案进行了比较论证,推荐采用真空触发间隙和支柱式单断口结构配电磁斥力操动机构的快速开关来提高电网运行可靠性。

关 键 词:串联电容器  触发间隙  快速开关  技术方案

Discussion of Design Technical Solutions on Series Compensation Capacitor Banks with Protective Gap and Bypass Switches
Authors:WU Sheng-gang  WANG Wei-dong  CHEN Guo-gui  GAO Yang  LI Yan-ru
Affiliation:( Henan High Voltage Apparatus Research Institute, Pingdingshan 467001, China )
Abstract:Analysis was made to the main purpose and its special operation conditions of series compensation capacitor with the protective gap and bypass switches. According to its main technical standards requirements, this paper put forward a variety of technical solutions of the trigger gap and high-speed switches. These technical solutions were analyzed and compared. This paper recommended adopting the vacuum trigger gap and pillar type of single fracture structure matched with electromagnetic repulsive force machine high-speed switch to improve the grid operational reliability.