摘    要:为青藏铁路供电的110kV沱沱河和五道梁变电站地处高寒永冻地区,如何在高寒永冻地区进行接地系统设计对变电站的建设十分重要。通过测试二次电缆和二次设备的绝缘耐受特性,提出可将地电位升高提高到5kV。采用电磁场数值计算方法对分层土壤中接地系统的电气参数进行计算, 分析比较了各种可行的高寒冻土地区接地系统的设计方案, 讨论了深垂直接地极的布置规律、水平地网的埋设深度、接地系统的均压优化布置对接地系统接地电阻、接触电压和跨步电压的影响。最终得出了坨坨河和五道梁两变电站的接地系统设计方案,并总结归纳了高寒冻土地区变电站接地系统的设计规律。

关 键 词:NULL
文章编号:1000-3673(2006)04-0060-05
收稿时间:09 12 2005 12:00AM
修稿时间:2005年9月12日

Grounding System Design of Wudaoliang and Tuotuohe Substations for 110kV Power Transmission Engineering of Qinghai-Tibet Railway
HE Jin-liang,KANG Peng,ZENG Rong,ZHANG Bo,HUA Pu-xiao.Grounding System Design of Wudaoliang and Tuotuohe Substations for 110kV Power Transmission Engineering of Qinghai-Tibet Railway[J].Power System Technology,2006,30(4):60-64.
Authors:HE Jin-liang  KANG Peng  ZENG Rong  ZHANG Bo  HUA Pu-xiao
Abstract:The 110kV Tuotuohe and Wudaoliang substations supplying power for Qinghai-Tibet railway locate in arctic-alpine permafrost area, so it is very important for the construction of substation how to design grounding system in arctic-alpine permafrost area. By means of measuring the insulation withstand properties of secondary cables and devices, it is proposed that the ground potential rise can be increased to 5kV. Applying the numerical analysis method of electromagnetic field to electrical parameter calculation of grounding system in layered soil, various feasible design schemes for grounding system in arctic-alpine permafrost area are analyzed and compared, the arrangement regularity of deeply-buried vertical grounding electrodes, the burial depth of horizontal grounding grid, the influence of grounding system's optimal arrangement on grounding resistance, touch voltage and step voltage of grounding system are researched. Eventually the grounding system design scheme for Tuotuohe and Wudaoliang substations is obtained. At the same time, the regular patterns of grounding system design in arctic-alpine permafrost area are summarized and induced.
Keywords:Qinghai-Tibet rail way  Substation  Permafrost  Multi-layer soil model  Grounding resistance  Touch voltage  Step voltage  High voltage engineering  Power system
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《电网技术》浏览原始摘要信息
点击此处可从《电网技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号