引用本文:曾昭华,蒋卫平,班连庚,武守远,李亚健.伊冯500 kV可控串补装置中限压器工作方式的实时仿真研究[J].电网技术,2000,24(11):23-27.
作者姓名:曾昭华  蒋卫平  班连庚  武守远  李亚健
作者单位:中国电力科学研究院,北京,100085
基金项目:中国科学院资助项目,电子工业部科研项目,东北电力集团公司资助项目,59637050,,,,,
摘    要:介绍利用实时仿真装置对东北伊冯500KV系统可控串补中限压器(MOV)工作方式的试验研究。试验包括故障和系统的暂态稳定控制,通过试验检验了以离线计算为基础的设计参数,对控制保护方式重新进行了分析研究,试验表明,当采用晶闸管旁路方法的保护限压器时,从实际控制器发出旁路命令到限压器能量停止上升需时5ms,长于数字计算得出的1-1.5ms。在暂态稳定试验中发现,即使在暂稳极限范围内,故障切除后,目前设计

关 键 词:电力系统  可控串补装置  限压器  实时仿真
文章编号:

A REAL-TIME SIMULATION STUDY ON OPERATION MODE OF TCSC VARISTOR IN YIMING-FENGTUN 500kV POWER SYSTEM
ZENG Zhao-hua,JIANG Wei-ping,BAN Lian-geng,WU Shou-yuang,LI Ya-jian.A REAL-TIME SIMULATION STUDY ON OPERATION MODE OF TCSC VARISTOR IN YIMING-FENGTUN 500kV POWER SYSTEM[J].Power System Technology,2000,24(11):23-27.
Authors:ZENG Zhao-hua  JIANG Wei-ping  BAN Lian-geng  WU Shou-yuang  LI Ya-jian
Abstract:A real time simulation study on the operation mode of TCSC varistor (MOV) in Yiming Fengtun 500kV system is presented in this paper. The study includes fault applying and transient stability controlling. The designed MOV parameters obtained from off line analysis are examined. The protection control modes are reviewed and studied. The study shows that using thyristor bypass to prevent MOV from overload may cause a 5 ms time delay which is longer than that obtained by off line analysis. It also shows that after fault clearing, even the system power flow is below the transient stability limits, the designed MOV can have unwanted conduction and may affect stability control adversely. In this paper, some disadvantages, such as being unreliable, of the original thyristor bypass design are pointed out. From the study, the protective level of Yiming Fengtun TCSC's MOV is suggested to be 2.4 pu instead of 2.2 pu and the allowable energy dissipation of MOV is 20 MJ.
Keywords:TCSC  MOV  transient stability